3.7 Disconnecting the high voltage cable
Warning!
Electric shock hazard!
Work may be carried out only if:
• the supply voltage to the generator has been disconnected,
• the machine is at a standstill because the bars pick up charges if the
material web is running.
Take off the clip at the KNH_ _ generators, the KNHV_ distributor boxes
and/or the R131 bar, using a 3 mm screw driver. Then pull out the cable.
Disconnect the union nut (SW18) at the POWER CHARGER PC_ _
generators. Then pull out the cable.