background image

8

BA-en-2088-2207_ES60

• The power supply must be checked regularly to ensure its proper func-

tioning. The connections of the high voltage cables must be free of dirt 
and other foreign matter (see 

chapter 5.1 "Power supply”, page 14

).

• Make sure that the bars are clean at all times. Dirt results in malfunc-

tions and in premature wear of the units.

• When cleaning do not soak the bars and the high voltage cable in sol-

vent and do not damage the emission tips; allow the solvent to evapo-
rate completely before restarting the unit (see 

chapter 5 "Maintenance”, 

page 14

chapter 6 "Trouble-shooting”, page 15

).

• Potential risk for wearers of cardiac pacemakers:

Moving the chest closer than 3.5 cm to the emission tips of the 
discharging bars or making surface contact with several emission tips 
(touching a single tip is not critical) can result in a temporary switchover 
of the cardiac pacemaker into the fault mode. Permanent proximity or 
contact can therefore cause severe problems. 

If it is likely that the chest of such a person comes closer than 3.5 cm to 
the emission tips of the discharging bar, or if several emission tips are 
touched at the same time, the appropriate warning notices must be 
displayed.

• The operation of the bars can generate ozone. The ozone concentra-

tion levels developing near the bars depend on many different factors 
such as site of installation, bar current and voltage, air circulation, etc., 
and can therefore not be specified in general terms. If the maximum 
allowable concentration of ozone must be observed at the site of instal-
lation of the bar, the concentration must be measured on site.

The AGW value (maximum admissible concentration) serves to assess 
the ozone concentration at the workplace. The user must make sure 
that the appropriate national AGW value is at no times exceeded, e.g. 
in Germany the ozone concentration occurring during the operation of 
the system must not exceed the recommended value based on interna-
tional limits of 0.06 ml/m³ (0.12 mg/m³).

2.4 Technical advance

The manufacturer reserves the right to make changes to the technical 
specifications without prior notice in order to adapt the units to state-of-
the-art engineering. Eltex will provide the latest information on any 
changes or modifications in the operating instructions on request.

Summary of Contents for ES60 Series

Page 1: ...Operating Instructions BASE IONIZER Series ES60 vario Power Supply for AC operation BA en 2088 2207 F01089y...

Page 2: ...2 BA en 2088 2207_ES60...

Page 3: ...ion blower pistols and distributors suitable for connection 10 3 4 Connecting the high voltage cable 10 3 5 Maximum active bar length and length of the high voltage cable 11 3 6 Connecting the supply...

Page 4: ...supply features the following characteristics 5 plug type high voltage outputs stable 5 kV AC output voltage optional function monitoring small dimensions easy installation protection class IP54 desig...

Page 5: ...d 2 High voltage terminals 5 pcs 3 Fuse type see name plate 4 ON OFF switch ON illuminated 5 Plug for functional signal only for functional monitoring optional 6 Grounding terminal 7 Mounting bracket...

Page 6: ...ers will not assume any liability and warranty if the units are used improperly or used outside the intended purpose 2 2 Identification of risks and hazards Possible risks and hazards resulting from t...

Page 7: ...t protection is no longer effective Always dis connect the power before opening the power supply units The protection class IP54 only applies if the housing cover is closed and the cable connections a...

Page 8: ...to the emission tips of the discharging bar or if several emission tips are touched at the same time the appropriate warning notices must be displayed The operation of the bars can generate ozone The...

Page 9: ...r supply is designed for wall mounting Attach using the brackets provided installation dimensions see Fig 2 The operating elements of the power supply and the terminals must be freely accessible at al...

Page 10: ...ble 3 4 Connecting the high voltage cable Warning Connect or disconnect the high voltage cables only with the power supply switched off Connect the discharging bars to the power supply using the prefa...

Page 11: ...zles R36E ion blower heads R55E and ion bower pistols PR36 and PR55 Example The maximum permissible total cable length with a 3 meter active bar length is 32 meters Fig 5 demonstrates this principle f...

Page 12: ...h voltage is supplied to the bars in this case For external security of the power supply the following circuit breaker is re commended Tripping Characteristic 2A K according to DIN EN 60947 2 3 7 Conn...

Page 13: ...n the switch lights up green High voltage is now supplied to the dis charging bars The output voltage is now a constant 5 kV AC If the fuse is defective the switch will not light up 4 2 Operating mode...

Page 14: ...according to the operating conditions The power supply itself does not require any maintenance Check for correct ground connection 5 2 Discharging bars To ensure the trouble free function of the disc...

Page 15: ...ny work involving the units must be carried out by qualified electrici ans Fault Cause Measure No high voltage Lamp in mains power switch lit transformer defective Lamp in mains power switch fails to...

Page 16: ...V AC Current max 6 2 mA Frequency 50 60 Hz pluggable connections 5 Load capacity depending on bar type and length and high voltage cable length see chapter 3 5 Features Ion balance with and without pa...

Page 17: ...BA en 2088 2207_ES60 17 8 Dimensions Z 118096y_2 Fig 7 Dimensions ES60 Power Supply...

Page 18: ...ly ES60 Plug S Set for prefabricating the high voltage cable without flexible tube for power supply ES60 Flexible tube for high voltage cable specify length Blanking plug for high voltage connection M...

Page 19: ...Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurement Electromagnetic compatibility EMC Limits Limit for harmonic current emissions...

Page 20: ...mbH Blauenstra e 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our...

Reviews: