2. Safety

The ES60 Power Supplies have been designed, built and tested using 
state-of-the-art engineering, and have left the factory in a technically and 
operationally safe condition. If used improperly, the units may neverthe-
less be hazardous to personnel and may cause injury or damage. Read 
the operating instructions carefully and observe the safety instructions.
For warranty conditions, please refer to the General Terms and Conditions 
(GTC), see www.eltex.de.

2.1 Proper use

The ES60 Power Supplies may be operated only in connection with the 
appropriate Eltex discharging bars for AC operation as well as the ion 
blower nozzles, ion blower pistols and distributors, , each with a perma-
nently connected high voltage cable.
Modifications or changes made to the power supplies are not permitted.
Use only original Eltex spare parts and equipment. 
The manufacturers will not assume any liability and warranty if the units 
are used improperly or used outside the intended purpose.

2.2 Identification of risks and hazards 

Possible risks and hazards resulting from the use of the power supplies 
are referred to in these operating instructions by the following symbols:

Warning!

This symbol appearing in the operating instructions refers to operations 
which, if carried out improperly, may result in serious personal injuries.

Caution!

This symbol appearing in the operating instructions refers to operations 
which, if carried out improperly, may result in damage to property.

2.3 Work and operational safety
Warning!

Carefully observe the following notes and the complete 

chapter 2 "Safety”, 

page 6

!

Always observe the rules and regulations applying in your country with re-
ference to electrical appliances.
• Before carrying out repairs, cleaning or maintenance work involving the 

power supplies and the discharging bars, switch off the power supply 
and disconnect the mains power supply (see 

chapter 5 "Maintenance”, 

page 14

chapter 6 "Trouble-shooting”, page 15

).

Summary of Contents for ES60 Series

Page 1: ...Operating Instructions BASE IONIZER Series ES60 vario Power Supply for AC operation BA en 2088 2207 F01089y...

Page 2: ...2 BA en 2088 2207_ES60...

Page 3: ...ion blower pistols and distributors suitable for connection 10 3 4 Connecting the high voltage cable 10 3 5 Maximum active bar length and length of the high voltage cable 11 3 6 Connecting the supply...

Page 4: ...supply features the following characteristics 5 plug type high voltage outputs stable 5 kV AC output voltage optional function monitoring small dimensions easy installation protection class IP54 desig...

Page 5: ...d 2 High voltage terminals 5 pcs 3 Fuse type see name plate 4 ON OFF switch ON illuminated 5 Plug for functional signal only for functional monitoring optional 6 Grounding terminal 7 Mounting bracket...

Page 6: ...ers will not assume any liability and warranty if the units are used improperly or used outside the intended purpose 2 2 Identification of risks and hazards Possible risks and hazards resulting from t...

Page 7: ...t protection is no longer effective Always dis connect the power before opening the power supply units The protection class IP54 only applies if the housing cover is closed and the cable connections a...

Page 8: ...to the emission tips of the discharging bar or if several emission tips are touched at the same time the appropriate warning notices must be displayed The operation of the bars can generate ozone The...

Page 9: ...r supply is designed for wall mounting Attach using the brackets provided installation dimensions see Fig 2 The operating elements of the power supply and the terminals must be freely accessible at al...

Page 10: ...ble 3 4 Connecting the high voltage cable Warning Connect or disconnect the high voltage cables only with the power supply switched off Connect the discharging bars to the power supply using the prefa...

Page 11: ...zles R36E ion blower heads R55E and ion bower pistols PR36 and PR55 Example The maximum permissible total cable length with a 3 meter active bar length is 32 meters Fig 5 demonstrates this principle f...

Page 12: ...h voltage is supplied to the bars in this case For external security of the power supply the following circuit breaker is re commended Tripping Characteristic 2A K according to DIN EN 60947 2 3 7 Conn...

Page 13: ...n the switch lights up green High voltage is now supplied to the dis charging bars The output voltage is now a constant 5 kV AC If the fuse is defective the switch will not light up 4 2 Operating mode...

Page 14: ...according to the operating conditions The power supply itself does not require any maintenance Check for correct ground connection 5 2 Discharging bars To ensure the trouble free function of the disc...

Page 15: ...ny work involving the units must be carried out by qualified electrici ans Fault Cause Measure No high voltage Lamp in mains power switch lit transformer defective Lamp in mains power switch fails to...

Page 16: ...V AC Current max 6 2 mA Frequency 50 60 Hz pluggable connections 5 Load capacity depending on bar type and length and high voltage cable length see chapter 3 5 Features Ion balance with and without pa...

Page 17: ...BA en 2088 2207_ES60 17 8 Dimensions Z 118096y_2 Fig 7 Dimensions ES60 Power Supply...

Page 18: ...ly ES60 Plug S Set for prefabricating the high voltage cable without flexible tube for power supply ES60 Flexible tube for high voltage cable specify length Blanking plug for high voltage connection M...

Page 19: ...Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurement Electromagnetic compatibility EMC Limits Limit for harmonic current emissions...

Page 20: ...mbH Blauenstra e 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our...

Reviews:

Related manuals for ES60 Series