2.2. Electrical insulation
The iLC CORE control gear has been designed in accordance with the EN 61347-1 and EN 61347-2-13 safety standards
for double or reinforced insulation against electric shocks resulting from contact with accessible parts.
The insulation between the primary and secondary circuits, as well as between every circuit and the functional earth,
is set out in the following table:
Mains
1-10V
Functional
earth
LED module
Accessible
parts
Mains
X
Basic
Double
Double
Double
1-10V
Basic
X
Double
Double
Double
Functional earth
Double
Double
X
Double
Double
LED module
Double
Double
Double
X
Double
Accessible parts
Double
Double
Double
Double
X
NOTE:
When the devices are built into luminaires, the cabling between the different components must observe the insulation class for
which these lighting fixtures have been designed, as well as comply with the EN 60598 standard.