Elster BK Series Operating Instructions For Operators And Installers Download Page 8

Deutschland

Elster GmbH
Postfach 129, D-55248 Mainz-Kastel
Steinern Straße 19-21, 55252 Mainz-Kastel

T +49 6134 605-0

F +49 6134 605-390
[email protected]
www.elster-instromet.com

GB-8

D

GB

F

NL

I

SK

W

re

se

rv

th

rig

ht

 to

 m

ak

te

ch

ni

ca

l m

od

ifi

ca

tio

ns

in

 th

in

te

re

st

of

 p

ro

gr

es

s.

United Kingdom

Elster Metering Limited
Elster Jeavons

Tollgate Business Park

Beaconside
Stafford, ST16 3EF

T +44 1785 275200

F +44 1785 275305
[email protected]
www.elstermetering.co.uk

Irland

Active Energy Control Ltd.

Unit 4, Clare Marts
Quin Road
Ennis, Co. Clare

T +353 65 6840600

F +353 65 6840610
[email protected]
www.aec.ie

Contact

Technical data

Application with diaphragm gas meters BK

RoHS compliant
Enclosure: IP 54
Battery life: approx. 15 years

Ambient temperature: -10 to +55°C
Ambient conditions according to directive 2044/22/EC: 

mechanical: class M1, 
electromagnetic: class E2.
Data logger for past meter readings: 
up to 20 weeks in 30 min. intervals.
Optical interface: pursuant to EN 62056-21, Mode 
(E), Annex B.2.
For further technical data on diaphragm gas meters 
BK – see Diaphragm meters BK-G1.6 to BK-G25 
and BK-G1.6T to BK-G25T operating instructions  

 http://docuthek.kromschroeder.com/doclib/main.

php?language=1&folderid=400041&by_class=2&by_
lang=-1
.

Declaration of conformity

Diaphragm gas meters BK..E (with electronic 

index)

We, the manufacturer, hereby declare that the prod-

uct BK, marked with No. DE-11-MI002-PTB001, 
complies with the requirements of the listed Directives 
and Standards.
Directive:

–   2004/22/EC (MID)

Standard:

–   DIN EN 1359:2007 (EN 1359:1998 + A1:2006)

Directive:

–   2004/108/EC (MID)

Standards:

–   OIML D11: 2004, Sec. 12,
–   EN 55022: 2006 + A1:2007

The relevant product corresponds to the tested type 

sample.

The production is subject to the surveillance proce-

dure pursuant to 2004/22/EC, Annex D, Physika-
lisch-Technische Bundesanstalt (German National 
Metrological Institute), Notified Body 0102.
Elster GmbH

Conformity with Directive 2004/22/EC is declared 
by affixing the following markings:

M...

 

0102

After the “M”, the year of construction is given.

Scan of the Declarations of conformity – see  
www.docuthek.com

Summary of Contents for BK Series

Page 1: ... Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see Part designations Report any trans port damage immediately Storage Store the product in a dry place Ambient tempera ture see Technical data Translation from the German D GB GB 1 Operating instructions for operators and installers Safety Contents Operating instructions for operators and installers ...

Page 2: ...5 Service cover 6 Service seal 7 Battery Type label Index plate BK G E DE 07 MI002 PTB001 002545632734 class 1 5 Q max Q min M10 0102 12345678 Installation Installing the gas meter For installing the gas meter in the pipe work refer to the operating instructions for diaphragm gas meters BK G1 6 to BK G25 and BK G1 6T to BK G25T see http docuthek kromschroeder com doclib main php language 1 folderi...

Page 3: ...n some menus may be missing The Current meter reading basic display appears when switching on the index If you are in a different menu the display will automatically change back to the basic display when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the basic display to the various menus such as Meter information using the user keys Menu overview...

Page 4: ...nce between the internal time recording and the actual time is too large This can lead to invalid consumption data After the next time syn chronization the consumption data are recorded again correctly and disappears Tariff totals If the optional tariff data are configured they can be called up here Tariff data with measured gas volumes are dis played by pressing the selection key Previous tariff ...

Page 5: ...n the display 2 Briefly press the selection key A further test pattern appears in the display 3 Hold the selection key pressed down The display switches to the previous menu Cyclic test The accuracy of the meter can be checked using a cyclic volume test Cyclic test Starting Cycles 0 0 0000 00 C 00 000000m3 U 00 000000m3 Press to abandon test C volume U volume temperature converted Cycles number of...

Page 6: ...replaced when the optical communication link has been established see Establishing an optical communication link p 6 Otherwise data will be lost 2 Initiate changing the battery The procedure depends on your user software Attention The battery may only be removed once a release message has been issued by the index As soon as the release message NOW READY TO CHANGE THE BATTERY PACK appears there is ...

Page 7: ...nufacturer 6 Re seal the service seal Check test The MID 2004 22 EC prescribes that the measur ing instrument in this case the BK should be able to be checked The accuracy of the meter must be checked by comparing the flow rates The requirements and test methods must comply with national laws and regulations The check should be carried out using the cyclic test see Service mode p 5 Assistance in t...

Page 8: ... Optical interface pursuant to EN 62056 21 Mode E Annex B 2 For further technical data on diaphragm gas meters BK see Diaphragm meters BK G1 6 to BK G25 and BK G1 6T to BK G25T operating instructions http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_class 2 by_ lang 1 Declaration of conformity Diaphragm gas meters BK E with electronic index We the manufacturer hereby de...