GB-6
D
GB
F
NL
I
SK
Calibration factors
▷
▷
The Elster internal metrological “Q” data are dis-
played.
Calibration factors
Q : 0.000m
3
/h
→
16384
Q : 6.000m
3
/h
→
16384
Q : 12.000m
3
/h
→
17203
Tc : Elektronic
Tb : 15°C
▷
▷
Temperature conversion Tc (OFF/mechanical/
electronic), reference temperature Tb.
– Tc: OFF (no temperature conversion)
or
– Tc: Mechanical
Tb: 15°C (reference temperature)
or
– Tc: Electronic
Tb: 15°C (reference temperature)
Establishing an optical
communication link
▷
▷
In order to configure the electronic index for the
respective application, the optical communication
link must be activated.
1
Position the opto-adapter head on the interface
provided.
12345
678
2
Press any user key.
▷
▷
Optical communication is enabled for 1 min.
▷
▷
If the optical communication link is not used dur-
ing this time, the interface will be deactivated.
Initiate communication.
▷
▷
The procedure depends on your user software.
Changing the battery
▷
▷
The battery is available as a spare part. Please
contact the manufacturer, see [Contact – p. 8].
1
Prepare the index for changing the battery.
BK-Gx
123
BK-Gx
12345
678
▷
▷
The battery can only be replaced when the optical
communication link has been established, see
[Establishing an optical communication link – p. 6].
Otherwise data will be lost.
2
Initiate changing the battery.
▷
▷
The procedure depends on your user software.
▷
▷
Attention! The battery may only be removed once
a release message has been issued by the index.
▷
▷
As soon as the release message “NOW READY
TO CHANGE THE BATTERY PACK” appears,
there is a 4-minute time period to remove the
battery. If the battery is not removed from the con-
tacts within this timeframe, the index will restart.
▷
▷
If the battery is not removed from the contacts
within the time provided, repeat the steps as of
point
2
.
Replace the battery.
BK-Gx
12
BK-Gx
12345
678
▷
▷
As soon as the new battery has been pushed
into the electronic index and onto the contacts,
the index starts and is in operation again after a
short time.
▷
▷
The basic display appears.
▷
▷
Optical communication is enabled for 1 min. If the
optical communication link is not used during this
time, the interface will be deactivated.
4
Reprogram the battery parameters.
▷
▷
The procedure depends on your user software.
Electronic index without communication module:
▷
▷
After the battery has been replaced, check the
time and update it if necessary. Note the global
UTC format.
5
Re-seal the service seal.