Elster BK-G1.6 Operating Instructions Manual Download Page 7

GB-7

D

GB

F

NL

I

SK

Declaration of conformity

Scan of the following Declarations of conformity – see 
www.docuthek.com

Diaphragm gas meters BK-G..M, BK-G..C, 

BK-G..MT, BK-G..CT

We, the manufacturer, hereby declare that the prod-

ucts labelled accordingly comply with the require-
ments of the listed Directives and Standards:

–   MID 

EC Directive: 2004/22/EC – MID 
Standard: DIN EN 1359:2007 
(EN 1359:1998+A1:2006)

   EC  type-examinations: 

DE-07-MI002-PTB001, DE-07-MI002-PTB002.

   The production is subject to the surveillance 

procedure pursuant to 2004/22/EC, Annex D, 
Physikalisch-Technische Bundesanstalt (German 
National Metrological Institute), Notified Body 0102.

   Markings:

  

M...

  0102, DE-07-MI002-PTB001 or  

DE-07-MI002-PTB002  

   After the “M”, the year of construction is given.

–   ATEX (only valid if marked on the meter)

   EC Directive: 94/9/EC – ATEX
   Standards: 

EN 13463-1:2009 
EN 13463-5:2011

   Tests and inspections:
   TÜV NORD CERT GmbH, Declaration of con-

formity – No. TÜV 11 ATEX 090370 X.

   The production is subject to the conformity 

assessment procedure pursuant to 94/9/EC, 

Annex VIII.

   Markings:
    II -/2 G c IIB TX.
Elster GmbH

Diaphragm gas meters BK-G..A, BK-G..AT

We, the manufacturer, hereby declare that the prod-

ucts labelled accordingly comply with the require-
ments of the listed Directives and Standards:

–   MID 

EC Directive: 2004/22/EC – MID 
Standard: DIN EN 1359:2007 
(EN 1359:1998+A1:2006)

   EC  type-examinations: 

DE-07-MI002-PTB001, DE-07-MI002-PTB002.

   The production is subject to the surveillance 

procedure pursuant to 2004/22/EC, Annex D, 
Physikalisch-Technische Bundesanstalt (German 
National Metrological Institute), Notified Body 0102.

   Markings:

  

M...

 0102, DE-07-MI002-PTB001 or 

DE-07-MI002-PTB002

    After the “M”, the year of construction is given.

–   EMC

   EC Directive: 2004/108/EC – EMC
   Standards: 

OIML D11:2004, Sec. 12 
EN 55022:2006+A1:2007

   Tests and inspections:
   EMC Test NRW GmbH: 

Test Report No. P09-Z-00005-001

Elster GmbH

Diaphragm gas meters BK-G..E

We, the manufacturer, hereby declare that the prod-

ucts labelled accordingly comply with the require-
ments of the listed Directives and Standards:

–   MID

   EC Directive: 2004/22/EC – MID
   Standard: DIN EN 1359:2007 

(EN 1359:1998+A1:2006)

   EC type-examinations: DE-11-MI002-PTB001
   The production is subject to the surveillance 

procedure pursuant to 2004/22/EC, Annex D, 
Physikalisch-Technische Bundesanstalt (German 
National Metrological Institute), Notified Body 0102.

 Markings:

  

M...

 0102, DE-11-MI002-PTB001 

   After the “M”, the year of construction is given.

–   EMC

   EC Directive: 2004/108/EC – EMC
   Standards: 

OIML D11:2004, Sec. 12 
EN 55022:2006+A1:2007

   Tests and inspections:
   EMC Test NRW GmbH: 

Test Report No. P10-Z-00086-002

–   ATEX (only valid if marked on the meter) 

EC Directive: 94/9/EC – ATEX

   Standards: 

EN 1127-1:2007

   Tests and inspections:
   TÜV NORD CERT GmbH, Declaration of con-

formity – No. TÜV 11 ATEX 093627 X.

   The production is subject to the conformity 

assessment procedure pursuant to 94/9/EC, 

Annex VIII.

   Markings:
    II -/3 G IIA T1.
Elster GmbH

Summary of Contents for BK-G1.6

Page 1: ...changes are prohibited Only use OEM spare parts Transport Diaphragm gas meters are always to be transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Content...

Page 2: ...cal index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te Temperature conversion mechanical electronic Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing sleeve optional Type label Index plate Diaphragm gas meters BK...

Page 3: ...gm gas meter BK with integrated valve make sure that no dirt particles get into the meter and thus into the valve The yellow sealing sleeve protects the pressure test point on the gas meter It may only be opened for connecting a pressure measuring line Use seals made from tested materials Elastomer seals or asbestos free flat seals from Elster are recommended For meters resistant to high temperatu...

Page 4: ...suitable spanner Functional safety and reliability are ensured only if the material combination of the screw connector and the pressure line are intermatched Only use the olive and the attached union nut supplied The olive is secured to the sealing sleeve When re ordering use original Parker EO pro gressive ring fittings PSR DPR 1 6 7 2 3 4 5 Use corrosion resistant seamless precision steel tube p...

Page 5: ... Smart Metering Diaphragm gas meters BK with integrated valve In the event that the diaphragm gas meter BK is fitted with an integrated valve see page 3 Diaphragm gas meters with integrated valve the gas supply can be connected or disconnected remotely Unless otherwise agreed the valve is open on delivery as standard WARNING The network provider is responsible for the safe remote shut down and res...

Page 6: ...s permitted see operating instructions for Electronic index for diaphragm gas meters BK E Technical data Diaphragm gas meters BK Gas type natural gas town gas propane and butane as gases of the first to third families pursuant to DIN EN 437 2003 DVGW Code of Practice G260 Max allowable operating pressure pmax see type label index plate Max allowable measuring range Qmin Qmax see type label index p...

Page 7: ...aminations DE 07 MI002 PTB001 DE 07 MI002 PTB002 The production is subject to the surveillance procedure pursuant to 2004 22 EC Annex D Physikalisch Technische Bundesanstalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 07 MI002 PTB001 or DE 07 MI002 PTB002 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 E...

Page 8: ...0610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ATEX legend Marking of explosion protection II Equipment group ll for general industries with the exception of mines 2 Category internal none external Category 2 Zone 1 3 Category internal none external Category 3 Zone 2 G Type of atm...

Reviews: