Elster BK-G1.6 Operating Instructions Manual Download Page 5

GB-5

D

GB

F

NL

I

SK

  

 Apply the test pressure slowly to the gas meter.

2

3

 

If a pressure measuring line has been retrofitted 
to the diaphragm gas meter, check this connec-
tion for tightness.

2

3

 4 

  After the tightness test, slowly vent the gas meter.

 5 

 If a pressure measuring line has been retrofitted 

to the diaphragm gas meter, protect the pressure 
test point against external access with a sealing 
sleeve and a seal.

Commissioning

Once the tightness test has been successfully com-
pleted, the gas meter is ready for operation.

 

Slowly open the manual valve.

BK-G..M with mechanical index

For pulse tapping, the pulse sensor IN-Z6x can be 
connected – see Data sheet for pulse sensor IN-Z6x 
(D, GB) 

→ 

www.docuthek.com 

→ 

Elster-Instromet 

→ 

Products 

→ 

Gas measuring devices 

 Diaphragm 

meters 

→ 

Pulse sensor IN-Z61.

BK-G..A with Absolute ENCODER 

index AE/Z6

Interface description for gas meters with 
ENCODER index – see Specification (D, GB) 

→ 

www.docuthek.com 

→ 

Elster-Instromet 

→ 

Prod-

ucts 

→ 

Gas measuring devices 

 Diaphragm 

meters 

 Smart Metering 

 Specification M-BUS 

or SCR+.

BK-G..A with Absolute ENCODER AE and 

communications module ACM

If the diaphragm gas meter BK-G..A is fitted with 
communications module ACM – for further commis-
sioning see Communications module ACM M-BUS 
WIRE, ACM SCR+ WIRE... or Communications mod-
ule ACM WAVE SYSTEM RF operating instructions (D, 
GB, NL) 

 www.docuthek.com 

 Elster-Instromet 

 

Products 

 Gas measuring devices 

 Diaphragm 

meters 

 Smart Metering.

BK-G..E with electronic index

For further commissioning of diaphragm gas 
meter BK-G..E with electronic index – see Elec-
tronic index operating instructions (D, GB) 

 

www.docuthek.com 

 Elster-Instromet 

 Prod-

ucts 

 Gas measuring devices 

 Diaphragm me-

ters 

 Smart Metering.

Diaphragm gas meters BK with integrated 

valve

In the event that the diaphragm gas meter BK is fitted 
with an integrated valve, see page 3 (Diaphragm gas 
meters with integrated valve), the gas supply can be
 
connected or disconnected remotely.
Unless otherwise agreed, the valve is open on delivery 
as standard.

 WARNING

–   The network provider is responsible for the safe 

remote shut-down and restart of the diaphragm 
gas meter.

–   The integrated valve does not assume the func-

tions of a safety shut-off valve.

... with valve variant Vp

 

Should the diaphragm gas meter BK be ordered 
with a valve Vp, but without control electronics to 
be complemented by a third party, the technical 
data of the control interface is to be requested 
from Elster GmbH and observed.

 

The manufacturer of the control electronics is 

responsible for creating the conditions required 
for safe operation of the valve. Instructions on 
commissioning and operation are to be taken 
from the operating instructions for the control 
electronics.

... with valve variant Vs (Smart Valve)

 WARNING

–   Depending on national regulations, a limited and 

technically safe gas flow rate in the customer’s 
open consumer piping is allowed, see page 
(Technical data).

–   Assessment of the non-critical gas flow rate with 

regard to amount and duration, which occurs 
when the valve is released, is to be defined by 
the network provider.

–   The minimum operating pressure on the inlet 

must not be undershot, see page 6 (Technical 
data). Otherwise, when the valve is r
eleased and 
if the customer’s consumer piping is open at the 
same time, the valve may be completely opened.

“Smart Valve” valve function

 

The “Smart Valve” is switched remotely by 

the data management system. The valve first 
switches to the “Released” position. From the 

“Released” position, the valve automatically 

switches to the “Open” position, if the down-
stream installation is tight.

Summary of Contents for BK-G1.6

Page 1: ...changes are prohibited Only use OEM spare parts Transport Diaphragm gas meters are always to be transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Content...

Page 2: ...cal index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te Temperature conversion mechanical electronic Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing sleeve optional Type label Index plate Diaphragm gas meters BK...

Page 3: ...gm gas meter BK with integrated valve make sure that no dirt particles get into the meter and thus into the valve The yellow sealing sleeve protects the pressure test point on the gas meter It may only be opened for connecting a pressure measuring line Use seals made from tested materials Elastomer seals or asbestos free flat seals from Elster are recommended For meters resistant to high temperatu...

Page 4: ...suitable spanner Functional safety and reliability are ensured only if the material combination of the screw connector and the pressure line are intermatched Only use the olive and the attached union nut supplied The olive is secured to the sealing sleeve When re ordering use original Parker EO pro gressive ring fittings PSR DPR 1 6 7 2 3 4 5 Use corrosion resistant seamless precision steel tube p...

Page 5: ... Smart Metering Diaphragm gas meters BK with integrated valve In the event that the diaphragm gas meter BK is fitted with an integrated valve see page 3 Diaphragm gas meters with integrated valve the gas supply can be connected or disconnected remotely Unless otherwise agreed the valve is open on delivery as standard WARNING The network provider is responsible for the safe remote shut down and res...

Page 6: ...s permitted see operating instructions for Electronic index for diaphragm gas meters BK E Technical data Diaphragm gas meters BK Gas type natural gas town gas propane and butane as gases of the first to third families pursuant to DIN EN 437 2003 DVGW Code of Practice G260 Max allowable operating pressure pmax see type label index plate Max allowable measuring range Qmin Qmax see type label index p...

Page 7: ...aminations DE 07 MI002 PTB001 DE 07 MI002 PTB002 The production is subject to the surveillance procedure pursuant to 2004 22 EC Annex D Physikalisch Technische Bundesanstalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 07 MI002 PTB001 or DE 07 MI002 PTB002 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 E...

Page 8: ...0610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ATEX legend Marking of explosion protection II Equipment group ll for general industries with the exception of mines 2 Category internal none external Category 2 Zone 1 3 Category internal none external Category 3 Zone 2 G Type of atm...

Reviews: