Elster BK-G1.6 Operating Instructions Manual Download Page 1

 www.docuthek.com

D

GB

F

NL

I

SK

© 2012 Elster GmbH

xx.xx Fx/ivd x.xxx

Safety

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations in force. These 
 instructions can also be found at www.docuthek.com.

Explanation of symbols

 • 

,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damages resulting 
from non-observance of the instructions and non-
compliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Transport

Diaphragm gas meters are always to be transported 
in the upright position. On receipt of the product, 
check that the delivery is complete (see Part desig-
nations). Report any transport damage immediately. 

Storage

Diaphragm gas meters are always to be stored in the 
upright position and in a dry place. Ambient tempera-
ture: see Technical data.

Contents

Operating instructions

Translation from the German

D

GB

F

NL

I

SK

GB-1

050886/00 · Edition 0.

Safety

Contents

Diaphragm gas meters  

BK-G.6 to BK-G5

Diaphragm gas meters  

BK-G.6 to BK-G5  . . . . . . . . . . . . . . . . . . . . . 
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 

Diaphragm gas meters BK-G1.6 to G25  . . . . . . 2
BK with integrated “Smart Valve” . . . . . . . . . . . . 2

Type code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2

Type label/Index plate. . . . . . . . . . . . . . . . . . . . . 2

ATEX identification . . . . . . . . . . . . . . . . . . . . . . . 3

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Temperature test point  . . . . . . . . . . . . . . . . . . 4

Connecting the pressure measuring line  . . . 4

Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 5

BK-G..M with mechanical index. . . . . . . . . . . . . 5
BK-G..A with Absolute ENCODER index AE1/Z6 . 5
BK-G..A with Absolute ENCODER AE2 and 

communications module ACM. . . . . . . . . . . . . . 5
BK-G..E with electronic index  . . . . . . . . . . . . . . 5
Diaphragm gas meters BK with integrated valve  5

Maintenance/Removal. . . . . . . . . . . . . . . . . . . 6

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 6

Declaration of conformity . . . . . . . . . . . . . . . . 7

ATEX legend  . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Summary of Contents for BK-G1.6

Page 1: ...changes are prohibited Only use OEM spare parts Transport Diaphragm gas meters are always to be transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Content...

Page 2: ...cal index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te Temperature conversion mechanical electronic Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing sleeve optional Type label Index plate Diaphragm gas meters BK...

Page 3: ...gm gas meter BK with integrated valve make sure that no dirt particles get into the meter and thus into the valve The yellow sealing sleeve protects the pressure test point on the gas meter It may only be opened for connecting a pressure measuring line Use seals made from tested materials Elastomer seals or asbestos free flat seals from Elster are recommended For meters resistant to high temperatu...

Page 4: ...suitable spanner Functional safety and reliability are ensured only if the material combination of the screw connector and the pressure line are intermatched Only use the olive and the attached union nut supplied The olive is secured to the sealing sleeve When re ordering use original Parker EO pro gressive ring fittings PSR DPR 1 6 7 2 3 4 5 Use corrosion resistant seamless precision steel tube p...

Page 5: ... Smart Metering Diaphragm gas meters BK with integrated valve In the event that the diaphragm gas meter BK is fitted with an integrated valve see page 3 Diaphragm gas meters with integrated valve the gas supply can be connected or disconnected remotely Unless otherwise agreed the valve is open on delivery as standard WARNING The network provider is responsible for the safe remote shut down and res...

Page 6: ...s permitted see operating instructions for Electronic index for diaphragm gas meters BK E Technical data Diaphragm gas meters BK Gas type natural gas town gas propane and butane as gases of the first to third families pursuant to DIN EN 437 2003 DVGW Code of Practice G260 Max allowable operating pressure pmax see type label index plate Max allowable measuring range Qmin Qmax see type label index p...

Page 7: ...aminations DE 07 MI002 PTB001 DE 07 MI002 PTB002 The production is subject to the surveillance procedure pursuant to 2004 22 EC Annex D Physikalisch Technische Bundesanstalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 07 MI002 PTB001 or DE 07 MI002 PTB002 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 E...

Page 8: ...0610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ATEX legend Marking of explosion protection II Equipment group ll for general industries with the exception of mines 2 Category internal none external Category 2 Zone 1 3 Category internal none external Category 3 Zone 2 G Type of atm...