7.4
Power-up and start-up
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION OR ELECTRIC ARC
• Do not install the equipment while the power supply is connected.
•
Cutoffthepowersupplytoallequipment,includinganyconnecteddevices,andremovethepowerfusesbeforeremoving
anycoversorhatches,orbeforeinstalling/uninstallingaccessories,hardware,cablesorwires.
•
AlwaysuseaproperlycalibratedVoltmetertomakesurethesystemispoweredoff.
• Do not touch the unshielded components or the terminals while they are live.
•
Makesurethereisaneffectiveearthconnection;ifthereisnot,earththeequipment.
• Before applying voltage to the equipment:
•
Makesureallprotectiveelements,suchascovers,hatchesandgrilles,arefittedand/orclosed.
•
Checkallwiringconnections.
NOTICE
MALFUNCTIONING OF THE EQUIPMENT
•
Makesurethewatermainsiscorrectlyconnected.
•
Makesuretherearenotrapsinthedrainageduct.
•
Makesurethesteamoutletclosureclampsareproperlytightened.
•
Makesuretherearenopocketsofcondensateorthrottlinginthesteamdeliverychannel.
To start the humidifier (with humidistat connected or probe connected if in proportional mode):
•
Checkthefillinganddrainnetwork(seesections:
"5.2 HYDRAULIC INSTALLATION" ON PAGE 17,
"5.3 WATER DRAINAGE SYSTEM" ON PAGE 18
"5.4 STEAM DISTRIBUTION IN THE AHU" ON PAGE 19)
;
•
Fitthepowerfuses;
• Connect the humidistat or the probe in accordance with the required operation (see section
;
•
Makesurethereisavoltage-freecontactorashort-circuit("jumper")betweenterminals7-8Enablingcontact
,
see
"13. WIRING DIAGRAMS" ON PAGE 39;
•
Activatetheisolatorinstalledoutsidethehumidifierandopenthewatersupplysource;
•
PresstheON/OFFkeyonthedooroftheelectricpanel;
•
Settherequiredhumiditysetpointto100%;
•
Thehumidifierstartsawaterfilling(
filling in progress
) and draining (
draining in progress
) phase;
• When draining is complete (
draining complete
),settherequiredhumiditysetpointasdesired;
• Set the type of control (internal/external) to be used and the required setpoint value;
•
Whenhumidityisrequested,thehumidifierstartsaboilerfillingcycle,fillingtotheminimumwaterlevelthatguarantees
rapid steam production;
•
Thehumidifierfullydrainsthewaterandreplacesitcyclically,performingthewashingprocedure,inordertomaintain