22
Compressor cycles
Compressor running hours
Perishable mode (on/off)
Statistic
Reporting period
Description
Average
temperature
24 hours
Continuously calculated from the highest and lowest registered
temperature.
Lowest
registered
temperature
24 hours
The lowest temperature for the last 24-hour period.
Highest
registered
temperature
24 hours
The highest temperature for the last 24-hour period.
Door opening
counts
7 days
This is a daily moving average over a seven-day period.
The display will report the
count as follows:1
– 999
door openings
The display will show 1 to
999
1,000
–
99,999
door
openings
The display will show 1.0 for
1000 to 1049 cnts
1.1 for 1,050 to 1,099 cnts
1.2 etc.
The
maximum
count
therefore is 99,999
Motion counts
(passers by)
7 days
As door opening counts
Traffic density
setting
0
– 1 – 2 or 3
The system recognises low, medium or high traffic but can
also manually be set at one of these values. This statistic
shows the current automatically or manually chosen setting.
Compressor
cycles
24 hours
As per motion counts.
Compressor
running hours
Running total
This will be a running total unless a factory reset is applied
which will erase ALL data in the control. When the memory is
erased in the field the compressor running hours remain but all
other statistical values are erased.
The total maximum count is 99,999, which equals (calculated
at 10 running hours/day) 9,999.9 days, which equals 27.4
years.
Perishable
mode
0 or 1
Mode off or on