THE CONTROL SETTINGS
The EMS has the following parameter values:
EMS-55 Parameter Default Settings
Parameter
Description
Degrees C
Range
Units
SP
Set Point
See US & LS
o
C
US
Upper Set Point
0-10
o
C
LS
Lower Set Point
0-10
o
C
DIF
Differential
0.0-9.9
o
C
CAL
Calibration
+/-9.9
o
C
RT
Minimum Rest Time
1-30
Minutes
DS
Delay to Stand-by
0-120
Minutes
LD
Light Switch Off Delay
0-120
Minutes
SR
Stand-by Restart Period
0-240
Minutes
CT
Refrigeration System Time
Elapse
1-100
Hours
CF
Display in
O
C or
O
F
0 or 1
Number
SSP
Stand-by Set Point
0.0-9.9
o
C
SD
Stand-by Differential
0.0-9.9
o
C
IPD
Uninterrupted Pull Down
Activation Temperature
0-80
o
C
DTT
Activation Temperature for
Freeze Up Protection Mode
-10-50
o
C
DE
Defrost Interval
1-199
Hours
DD
Defrost Duration
1-199
Minutes
DT
Defrost Termination
1-80
o
C
FCO
Evaporator Fan Cycle On
Time
1-30
Minutes
FCF
Evaporator Fan Cycle Off
Time
1-30
Minutes
FSP
Fan Set Point
0-80
o
C
HT
Blocked Condenser
Temperature Alarm
50-250
o
C
D2
Display Stability
1-254
Units
HI
Over Voltage Protection
90-250
Units
LO
Under Voltage Protection
90-250
Units
BO
Buzzer Enable/Disable
0 or 1
Off/On
B1
Alarm Buzzer Sounding
Time
1-254
Seconds
AD
Alarm Delay
1-30
Minutes
AF
Activity Frequency
0= Low
Unit
1=Medium
2=High
3= Auto
PER
Perishable mode
0 or 1
Off/on
Summary of Contents for EMS-55