Multifunctional Actuators

Item numbers 70530 (KNX S4-B10 230 V), 70531 (KNX S2-B6 230 V), 70532 (KNX S1-B2 230 V)

EN

Installation and Ad justment

Summary of Contents for KNX S1-B2 230 V

Page 1: ...KNX S4 B10 230 V KNX S2 B6 230 V KNX S1 B2 230 V Multifunctional Actuators Item numbers 70530 KNX S4 B10 230 V 70531 KNX S2 B6 230 V 70532 KNX S1 B2 230 V EN Installation and Adjustment...

Page 2: ......

Page 3: ...actuator 13 2 4 2 Using an external voltage 13 2 5 Connecting example for binary inputs KNX S1 B2 230 V 14 2 5 1 Using the internal auxiliary voltage of the actuator 14 2 5 2 Using an external auxili...

Page 4: ...tching switch functions 66 4 3 2 3 Blocking function switch functions 67 4 3 2 4 Scenes switch functions 68 4 3 3 Button input switch functions 68 Input as bus button 68 Input as actuator button 68 5...

Page 5: ...eshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous s...

Page 6: ...4 Clarification of signs...

Page 7: ...necting two switchable devices light fan KNX S4 B10 4 outputs KNX S2 B6 2 outputs KNX S1 B2 1 output Keypad with button pairs and status LEDs Binary inputs for use as hand switches or as bus switches...

Page 8: ...puts 50 m Data output KNX Bus connector terminal BCU type own microcontroller PEI type 0 Goup addresses max 1024 Assignments max 1024 Dimensions approx 107 x 88 x 60 W H D mm 6 dividing units Weight a...

Page 9: ...at risk free operation is no longer guaranteed The device is only to be used for its intended purpose Any improper modification or failure to follow the operating instructions voids any and all warran...

Page 10: ...tion of these operating instructions 2 2 Connection Follow the guidelines and standards for SELV electric circuits while installing and cable laying of the KNX connection and inputs Binary inputs The...

Page 11: ...ly with terminal No 1 6 Binary inputs 1 6 1 and 2 two bridged connections 7 Internal auxiliary voltage 24 V DC Only for binary inputs Do not assign any external voltage 8 Binary inputs 7 10 9 Up Down...

Page 12: ...PRG 4 Bus terminal slot KNX 5 N bridged internally with terminals No 1 6 Binary inputs 1 2 two bridged connections 7 Internal auxiliary voltage 24 V DC Only for binary inputs Do not assign any externa...

Page 13: ...programmed via the ETS No automatic functions are executed Flashes Green on Orange flashing Programming mode active 1 Programming LED and programming but tons PRG 2 Bus terminal slot KNX 3 Switch pair...

Page 14: ...tation sends a value every 5 minutes the actuator must be configured for a monitor ing period of 15 minutes Behaviour LED To top Drive in top end position device on To bottom Drive in bottom end posit...

Page 15: ...4 Connection examples for binary inputs KNX S4 B10 and KNX S2 B6 2 4 1 Using the internal auxiliary voltage of the actuator 2 4 2 Using an external voltage Other binary inputs corresponding External...

Page 16: ...ors excepted 2 5 Connecting example for binary inputs KNX S1 B2 230 V 2 5 1 Using the internal auxiliary voltage of the actuator 2 5 2 Using an external auxiliary voltage According to additional binar...

Page 17: ...ing 4 Bit 54 Input 1 encoder 8 bit Output R CT 5 5 xxx 1 Byte 55 Input 1 encoder temperature Output R CT 9 1 DPT_Value_Temp 2 Bytes 56 Input 1 encoder brightness Output R CT 9 4 DPT_Value_Lux 2 Bytes...

Page 18: ...omatic slat position Input RWC 5 1 DPT_Scaling 1 Byte 109 Channel A switch from manual to automatic Input RWC 1 1 xxx 1 Bit 110 Channel A automatic blocking object Input RWC 1 1 DPT_Switch 1 Bit 111 C...

Page 19: ..._Switch 1 Bit 133 Channel A inside temperature release measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 134 Channel A inside temperature release target value Input RWC 9 1 DPT_Value_Temp 2 Bytes...

Page 20: ...Input RWC 9 1 DPT_Value_Temp 2 Bytes 154 Channel A warm air supply outside temperature measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 155 Channel A warm air supply blocking target value Input...

Page 21: ...annel A slave zero position status Input RWC 1 1 DPT_Switch 1 Bit 175 Channel A master zero position status Input RWC 1 1 DPT_Switch 1 Bit 176 Channel A master zero position command Input RWC 1 1 DPT_...

Page 22: ...A block 3 rain blocking object Input RWC 1 1 DPT_Switch 1 Bit 196 Channel A block 4 blocking object Input RWC 1 1 DPT_Switch 1 Bit 197 Channel A block 4 wind blocking object Input RWC 9 5 DPT_Value_Ws...

Page 23: ...1 1 DPT_Switch 1 Bit 222 Channel A2 status Readable R C 1 1 DPT_Switch 1 Bit 223 Channel A2 blocking object Input RWC 1 1 DPT_Switch 1 Bit 225 Channel A2 start stair case light function Input WC 1 10...

Page 24: ...nually Input RWC 1 1 DPT_Switch 1 Bit 315 Channel B Learn object 0 position memory manually Input RWC 1 1 DPT_Switch 1 Bit 316 Channel B Learn object 1 position memory manually Input RWC 1 1 DPT_Switc...

Page 25: ...t RWC 9 4 DPT_Value_Lux 2 Bytes 339 Channel B shading brightness Measurement value 3 Input RWC 9 4 DPT_Value_Lux 2 Bytes 340 Channel B shading threshold value Input output RWCT 9 4 DPT_Value_Lux 2 Byt...

Page 26: ...359 Channel B inside temperature opening target value Input RWC 9 1 DPT_Value_Temp 2 Bytes 360 Channel B inside temperature opening threshold value Input output RWCT 9 1 DPT_Value_Temp 2 Bytes 361 Ch...

Page 27: ...l B block 1 wind blocking object Input RWC 1 1 DPT_Switch 1 Bit 382 Channel B block 1 wind blocking Measurement value Input RWC 9 5 DPT_Value_Wsp 2 Bytes 383 Channel B block 1 wind blocking status Out...

Page 28: ..._Value_Wsp 2 Bytes 403 Channel B block 5 wind blocking status Output R CT 1 1 DPT_Switch 1 Bit 404 Channel B block 5 rain blocking object Input RWC 1 1 DPT_Switch 1 Bit 405 Channel B Movement limitati...

Page 29: ...el C status automatic or manual Output R CT 1 1 xxx 1 Bit 501 Channel C manual long term Input RWC 1 8 DPT_UpDown 1 Bit 502 Channel C manual short term Input RWC 1 8 DPT_UpDown 1 Bit 503 Channel C man...

Page 30: ...ct Input RWC 1 1 DPT_Switch 1 Bit 526 Channel C outdoor temperature blocking measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 527 Channel C outdoor temperature blocking status Output R CT 1 1 DP...

Page 31: ...s 548 Channel C cold air supply blocking object Input RWC 1 1 DPT_Switch 1 Bit 549 Channel C cold air supply outside temperature measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 550 Channel C co...

Page 32: ...asurement value Input RWC 9 7 DPT_Value_Humidit y 2 Bytes 567 Channel C inside humidity opening status Output R CT 1 1 DPT_Switch 1 Bit 570 Channel C zero position reached Input RWC 1 1 DPT_Switch 1 B...

Page 33: ...89 Channel C block 2 rain blocking object Input RWC 1 1 DPT_Switch 1 Bit 590 Channel C block 3 blocking object Input RWC 1 1 DPT_Switch 1 Bit 591 Channel C block 3 wind blocking object Input RWC 1 1 D...

Page 34: ...3 Channel C1 blocking object Input RWC 1 1 DPT_Switch 1 Bit 615 Channel C1 start stair case light function Input WC 1 10 DPT_Start 1 Bit 616 Channel C1 start stop stair case light function Input RWC 1...

Page 35: ...Input RWC 5 1 DPT_Scaling 1 Byte 709 Channel D switch from manual to automatic Input RWC 1 1 xxx 1 Bit 710 Channel D automatic blocking object Input RWC 1 1 DPT_Switch 1 Bit 711 Channel D current mov...

Page 36: ...tch 1 Bit 733 Channel D inside temperature release measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 734 Channel D inside temperature release target value Input RWC 9 1 DPT_Value_Temp 2 Bytes 735...

Page 37: ...Input RWC 9 1 DPT_Value_Temp 2 Bytes 754 Channel D warm air supply outside temperature measurement value Input RWC 9 1 DPT_Value_Temp 2 Bytes 755 Channel D warm air supply blocking target value Input...

Page 38: ...nel D slave zero position status Input RWC 1 1 DPT_Switch 1 Bit 775 Channel D master zero position status Input RWC 1 1 DPT_Switch 1 Bit 776 Channel D master zero position command Input RWC 1 1 DPT_Sw...

Page 39: ...D block 4 blocking object Input RWC 1 1 DPT_Switch 1 Bit 796 Channel D block 4 wind blocking object Input RWC 1 1 DPT_Switch 1 Bit 797 Channel D block 4 wind blocking measurement value Input RWC 9 5 D...

Page 40: ...1 2 DPT_Bool 1 Bit 818 Channel D1 Call up saving scenes Input RWC 18 1 DPT_SceneControl 1 Byte 820 Channel D2 switching Input RWC 1 1 DPT_Switch 1 Bit 821 Channel D2 feedback Output R CT 1 1 DPT_Swit...

Page 41: ...ssible in case of a bus voltage supply failure 4 2 Inputs Only for S4 B10 230 V and KNX S2 B6 230 V For KNX S1 B2 button inputs are directly parametrized in the settings of the output channels Set the...

Page 42: ...zero position sensor Input 4 Input 4 Input 2 Actuator button for output channel A Bus button Input 5 Input 5 Actuator button for output channel B Bus button For drives also zero position sensor Input...

Page 43: ...Bus function Switch Selector switch Shutter Blind Awning Window Dimmer 8 bit encoder Temperature encoder Brightness encoder Scenes Function Switch Command when pressing the button send 0 send 1 do no...

Page 44: ...in the general part of chapter Control modi for drive control page 70 The input can be blocked using a blocking object For active blocking there is no bus communication Input as dimmer If the input is...

Page 45: ...e temperature control may be ch anged for example The input can be blocked using a blocking object For active blocking there is no bus communication Input as brightness encoder If the input is assigne...

Page 46: ...automatic see Control drives page 47 Automatic functions Automatic can be specified externally or internally see Automatic internal for shading drives page 55 or Automatic for windows drives page 60...

Page 47: ...lly The actuator specifies the end positions with help from the greater current on the drive output For this regu lar reference movements see below should be set If a dead time is observed while start...

Page 48: ...ng a change of direction of the drive should be adjusted according to the specifications of the motor manufacturer Reference movement With the regular movement to the two end positions the runtime and...

Page 49: ...each other e g an awning and a window which is about to open One of two drive mechanisms is prioritised and is parameterised as master and the other one as slave By means of zero position sensors bot...

Page 50: ...ndow shall be opened The window knows the status of the awning not safe position and therefore submits a master command to the awning This is the signal for the awning to retract a little bit As soon...

Page 51: ...ems Blocking X will appear see chap ter Block blocking objects page 51 Block wind blocking page 52 and Block rain blocking page 53 The priorities of the blocking objects correspond to the sequence lis...

Page 52: ...k 2 no yes with blocking object yes as wind blocking yes as rain blocking Use block 3 no yes with blocking object yes as wind blocking yes as rain blocking Use block 4 no yes with blocking object yes...

Page 53: ...s drives page 60 appears Block blocking objects The menu item only appears if a block with blocking object was configured for cont rol Here it is specified was happens for object value 1 and 0 Via the...

Page 54: ...and awning close command open command window Position in only if by using a block a specific position is achieved 0 100 Slat position in only if by using a block a specific shutter position is achieve...

Page 55: ...For automatic operation after blocking follow automatic Type of input object 16 bit As of wind speed in m s blocking 2 30 5 If blocking is active no action stop move into position up command down com...

Page 56: ...ement and the slat position can be stored Position in only if by using a block a specific position is achieved 0 100 Slat position in only if by using a block a specific shutter position is achieved 0...

Page 57: ...utomatic information about brightness twilight outdoor and indoor temperature time and position of the sun must be present in the bus system Outdoor temperature block The input object outdoor temperat...

Page 58: ...ct indoor temperature release is linked with the output object of a tem perature sensor The input object can be a 1bit object smaller or larger than a th reshold value as well as a 16bit object measur...

Page 59: ...two or three 16bit objects measurement values e g East South and West sun can be used 1 x 1 bit input object Set the delay times for shading prevents constant opening and closing when light con ditio...

Page 60: ...r Parameter Shading threshold value in klux 0 100 30 Drive up delay in min 0 255 12 Drive down delay in min 0 30 1 Send current shading status No Yes Shading threshold specification per communication...

Page 61: ...can be set A fixed curtain and slat position is specified for each Azimuth to 0 360 Elevation from 0 90 Elevation to 0 90 Position of the sun is defined via directions regarding azimuth and elevation...

Page 62: ...tion object In order to fully utilize the internal ventilation automatic information about the outdoor and indoor temperature and the inside air humidity must be present in the bus system Cold supply...

Page 63: ...sis and blocked if the outdoor measurement value is greater than or equal to the indoor measurement value difference 16bit input object target actual temperature For this function the target value and...

Page 64: ...hold value is received via the communication object and can be changed ad ditionally e g button for target temperature and Open window never if too high temperature if too high room air humidity if to...

Page 65: ...input object then enter the opening position in If the ventilation is controlled by temperature and humidity via a 16bit input object then you can either set an opening position or open the windows in...

Page 66: ...s from 3 upwards of KNX S2 B6 and KNX S4 B10 are designated by default for operating the devices on the outputs channels and are therefore parametrized directly in the settings of the output channels...

Page 67: ...failure Input as zero position sensor The zero position sensor is used for the movement range limit of the respective drive see Channel settings drives page 45 In case of a defect zero position senso...

Page 68: ...ventilator will only start if the light has already been turned on for a few minutes The switch off delay effects that the ventilator will follow up if the button was operated again and the light is a...

Page 69: ...nally it is specified if the time interval for a repeat receipt of a switch on telegram is extended triggered again e g by pressing the button again and what happens when a switch off telegram arri ve...

Page 70: ...tch functions The inputs 1 and 2 of KNX S1 B2 and the inputs from 3 upwards of KNX S2 B6 and KNX S4 B10 are designated for operating the devices on the outputs channels and are therefore parametrized...

Page 71: ...ct the bus function Selector switch and specify what happens when pressing and releasing the button The input can be blocked using a blocking object No operation is possible for an active block Button...

Page 72: ...tally or stops The time difference between short and long and the repeat interval is set individually Comfort mode In the comfort mode pushing the button briefly a bit longer and long will trigger dif...

Page 73: ...age 47 The ex amples and the communication object numbers refer to the mutual master slave cou pling of drives at the output channel A and channel B Point in time 0 Push of button start of time 1 Rele...

Page 74: ...he actuator drive channel B is Slave zero position sensor via bus IN 3 IN 5 zero position zero position Master Drive 1 at channel A Slave Drive 2 at channel B Master command Master zero position statu...

Page 75: ...s Slave zero position sensor via bus IN 5 zero position zero position of drive 1 of drive 2 Master Drive 1 at channel A Slave Drive 2 at channel B Master command Master zero position status Slave zero...

Page 76: ...ommunication object Channel A1 switch 200 the light is turned on or off normally When switching via object Channel A1 staircase light func tion start 205 the staircase light time function is activated...

Page 77: ...bH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49...