Rain/Wind Sensor KNX RW

Technical specifications and installation instructions

EN

Elsner Elektronik GmbH 

Control and Automation Engineering

Herdweg 7
D – 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0

[email protected]

Germany

Fax

+49 (0) 70 56 / 93 97-20

www.elsner-elektronik.de

Summary of Contents for KNX RW

Page 1: ...ifications and installation instructions EN Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany Fax 49 0 70...

Page 2: ...ith adjustable threshold values Threshold values can be set by parameter or via communication objects 8 AND and 8 OR logic gates with each 4 inputs Every switching incident as well as 8 logic inputs i...

Page 3: ...ins voltage National legal regulations are to be observed Installation inspection commissioning and troubleshooting of the device must only be carried out by a competent electrician Disconnect all lin...

Page 4: ...ner Elektronik does not assume any liability for changes in standards after publica tion of this instruction manual 2 2 Location Select an assembly location at the building where precipitation and win...

Page 5: ...nt The mount comes adhered by adhesive strips to the rear side of the housing Fasten the mount vertically onto the wall or pole Fig 3 When wall mounting flat side on wall crescent shaped collar upward...

Page 6: ...e plan Fig 6 Example uses of the hinge arm mounting With the hinge arm mounting the sensor peeps out from beneath the roof overhang Fig 7 Example uses of the hinge arm mounting Fit ting to a pole with...

Page 7: ...ft and right along the bottom edge see Fig Re move the cover Proceed carefully so as not to pull off the wire connecting the PCB in the bottom part with the rain sensor in the cover soldered cable con...

Page 8: ...r 24V devices the connection cable must be plugged in between the cover and circuit board 2 3 4 PCB Layout 230 V AC version Fig 10 1 Cable connection to the rain sensor in the housing cover 2 Opening...

Page 9: ...for cable connection to the rain sensor in the housing cover 2 Tension clamp for voltage supply 24 V DC 20 V AC sui table for massive conductors of up to 1 5 mm or conduc tors with fine wires 3 Openin...

Page 10: ...d thus all other wind switching outputs may only be sup plied 60 seconds after the supply voltage has been connected After the auxiliary voltage has been applied the device will enter an initialisatio...