9
Establish wireless connection
Ventilation Unit WL800
• Version: 28.04.2016 • Errors and technical modifications subject to change without notice.
3. Pull the blower unit down parallel to the housing.
2.5. Connection
Connect the mains voltage (230 V AC continuous voltage):
3.
Establish wireless connection
To establish the wireless connection, the fan cover does not need to be removed.
4. Set the control unit and/or remote control or the button to teaching mode (observe
the corresponding manual/data sheet).
5. Switch on the power supply to the fan and/or shut off the power supply briefly if
the unit is already supplied with power.
6. The fan will send a "Teach" telegram every 10 seconds for 5 minutes after connect-
ing the power.
7. The wireless connection will be established automatically. The building control
system will display "Device has been taught".
The fan will stop sending "Learn" telegrams once the reply "taught" (for a learning pro-
cess) or a control command (in the event of a power failure during operation) is re-
ceived from a control unit.
4.
Maintenance
The function of the unit should be checked by the specialized dealer/installation tech-
nician once a year and the ventilation device cleaned from any dirt. No aggressive de-
tergents must be used for cleaning.
5.
Operation with remote control Remo 8
A
briefly pressing the arrow keys
adjusts the speed of the fan in 10% increments
(10 fan speeds altogether).
Longer pressing of the arrow keys
changes the speed continuously. If you release
the key, the speed stops changing.
Note:
Radio interference (rarely) may cause the speed to continue changing after the
key is released. In this case, briefly press the key again to stop it.
green-yellow
Protective conductor
1
Neutral conductor
2
Outer conductor L1