background image

 

iS320/iS320D SWING GATE OPENER MANUAL 

C. INSTALLATION 

 

 

1)  Check that the motor mounting position on the gate pillar can be done with the measurements 

in 

Table 1

 and 

Graph 1.

  

 
2)  Fix the pillar support as shown in 

(Fig.1 Page5) 

shortening or extending the support according 

to the dimensions A and B shown in the 

(Table1 Page 4). 

The support should be fixed at a 

height where the gate has a sufficiently rigid surface to fix the gate support, bearing in mind 
that the gate support will be fixed 

15 mm lower

 than the pillar support. 

(Fig.1 Page 10).

 

 

3)  Shorten or lengthen the gate support according to the dimensions for C shown in the table on 

page 3. Connect the iS320 opener to the gate support, with the rod completely extended 

(Fig.2 Page 5) 

and with the swivel joint nut fully tightened 

(Fig.3 Page 5). 

Once this has been 

done use a spirit level 

(Fig.4 Page 5) 

to mark the position of the gate support on the gate. 

Dismantle the gate support and fix it to the gate using the markings previously made. 

 

4)  Mount the motor and unscrew the swivel joint nut three 

turns to ensure closure. Attach the security ring and the 
safety bolt supplied. 

(Fig.6 Page 5).

 

 

5)  Electrical connections: Unscrew the end cover and 

connect the terminals according to the following diagram 

 
 

6)  Open the door manually to the desired open position, slide 

the collar stopper along the arm 

(Fig.9 Page 5) 

up to the 

front cover plate, fixing its position with the Allen key. The hydraulic transmission can then be 
plugged in and started. Re-position the collar stopper to achieve the desired position. 

 
7)  Once the motor is working correctly the limit valves can be adjusted 

(Fig.10 Page 5). 

The limit 

valves control the force and are independent in opening (blue limit valve) and closing (red limit 
valve) the gate. The screws can be adjusted by turning them a maximum of 45º and should be 
adjusted slightly above the minimum, in this way the force of the hydraulic system is reduced 
thus increasing safety.  

 

8)  The closing buffer can then be adjusted 

(Fig.11 Page 5)

, thus avoiding the door banging 

closed. To adjust the closing buffer turn the screw a maximum of 10º( If the buffer valve is 
completely closed then 15mm of buffering will be lost) . 

 

9)  The aluminium arm cover can then be placed back into position 

(Fig.12 Page 5), 

followed by 

its plastic cover and the end cover

.

 

 

 

 

 

 

Summary of Contents for iS320

Page 1: ...iS320 iS320D SWING GATE OPENER MANUAL iS320 iS320D HYDRAULIC SWING GATE OPENER USER MANUAL...

Page 2: ...1 2 INSTALLATION A INSTALLATION CHECK P 2 B BRACKET MOUNTING DIMENSIONS P 3 C INSTALLATION P 4 D LOCKING ACTUATOR P 6 E EMERGENCY RELEASE P 6 F BAC ANTI WIND SYSTEM P 7 G TECHNICAL DATA P 7 H KIT CONT...

Page 3: ...ranteed if the equipment is properly earthed 7 Installation requires qualified personnel with mechanical and electrical skills 8 Keep the automatic controls remote push buttons key selectors etc place...

Page 4: ...Hinges are properly positioned and greased 4 There should be no friction between the two gate leafs 5 There should be no friction with the ground while moving the gates 6 Check that the gate structure...

Page 5: ...5 70 Outward Opening 85 130 120 80 90 120 120 80 95 110 120 80 100 100 120 80 In some installations it might not be possible to follow the exact dinemsions in the above table due to a number of reason...

Page 6: ...o ensure closure Attach the security ring and the safety bolt supplied Fig 6 Page 5 5 Electrical connections Unscrew the end cover and connect the terminals according to the following diagram 6 Open t...

Page 7: ...iS320 iS320D SWING GATE OPENER MANUAL 5...

Page 8: ...CY RELEASE SYSTEM In an event of power failure the iS320 can be operated manually For manual operation open up the cover shown in the picture and turn the valve 360 anti clockwise Now the gate can be...

Page 9: ...lue is for the closing cycle Opening these valve will increase the pressure and closing will decrease the pressure If these valves are slightly opened they serve as an excellent anti wind system G TEC...

Page 10: ...iS320 iS320D SWING GATE OPENER MANUAL H KIT CONTENTS 8...

Page 11: ...r motor support 5 Gate motor support 6 Motor cables 7 Allen key for pressure adjustment 8 Support plate 9 Setup nuts and bolts 10 End cover for the arm 11 Wire housing 12 Stopper bracket 13 Hinge set...

Page 12: ...If it is used in high traffic area a more regular maintenance should be performed Disconnect the power supply 1 Clean and lubricate the screws the pins and the hinge with grease 2 Check the fastening...

Page 13: ...iS320 iS320D SWING GATE OPENER MANUAL Service History Date Maintenance Installer...

Page 14: ...UAL Domestic Industrial Sliding Gate Kits Domestic Industrial Swing Gate Kits FOB Remotes Locking Actuator Magnetic Locks Wireless Keypads Pre formed Loop Visit www elsema com to see our full range of...

Reviews: