Operation
MicroLink 33.6TQV / MicroLink 28.8TQV / MicroLink 14.4TQ
Manual © 1997 ELSA GmbH
75
automatic callback function. Up to 19 different user passwords can be stored
with the AT$P command (see page 71).
*E
Enable remote configuration
* AT*E0 : Remote configuration off
AT*E1 : Remote configuration on
The AT*E command is used to enable or disable the remote configuration.
The AT*E0 command disables the remote configuration.
The AT*E1 command enables the remote configuration.
When a connection has been established, the modem is in the online state as usual. However, once
the configuration command is entered, which consists of four characters (default setting: ****, see
also register S34, page 57), followed by a valid command line, the modem enters the configuration
mode. This allows the modem to temporarily leave the online transmission without aborting the
connection.
Configuration
The configuration command is only recognized in the online transmission
command
state.
Valid command
A valid command line begins with an AT or at and is terminated with Enter.
line
The A/ or a/ command is not valid after the configuration command. Also, a
valid command line is limited to 40 characters.
The user at the remote modem is prompted to identify himself by entering his user password. If his
entries are correct, the message PASSWORD OK is displayed, and the remote configuration is active.
If the remote configuration is used in combination with the automatic callback function with password
protection, the password is requested directly after the connection establishment, and therefore the
remote configuration becomes active immediately after the valid configuration command.
Example:
ELSA MICROLINK
PASSWORD
: ********
PASSWORD OK
REMOTE CONFIGURATION ACTIVE
OK
>
à
NOTE
à
The prompt ( > ) indicates that you are in configuration mode. Locked
commands are answered with ERROR.
*U
Save remote configuration settings
AT*U : Save current remote configuration