For the devices
TAR 1370-2, TAR 1370-2 H, TAR 1380-2, TARN 1370-2, TARN 1380-2, TARN 21370-2, TARN 21380-2 we state the following:
When operated in accordance with the technical manual, the criteria have been met that are outlined in the EMC Directive
2014/30/EC and the Low Voltage
Directive
2014/35/EC. This declaration is valid for those products covered by the technical manual which itself is part of the declaration.
Following standards were consulted for the conformity testing to meet the requirements of EMC and Low Voltage Guidelines:
EN 55011:2016, EN 61010-1:2010, EN 61326-1:2013
CE marking of year: 2017
This statement is made for the manufacturer / importer
by:
ELREHA Elektronische Regelungen GmbH
Werner Roemer,
Technical Director
D-68766 Hockenheim
www.elreha.de
Hockenheim
......
10.4.2017
.......................................................................
(
Name / Address
)
C
ity Date
S
ignature
EC Declaration of Conformity
Installation / Start-Up
Sensor locations
Control Sensor:
In the airflow, at the suction side of the evaporator.
Limit Sensor:
In the lamella core or the contact pipe of the evaporator,
at the place ice remains the longest time.
Applications with Airflow-Defrost
With this defrost method, there is no need for a defrost sensor in the
evaporator, so the sensor can be disabled. If the correction parameter
P20 is set to -10,1, the display shows "oFF" and the sensor is disabled.
Correcting the parameter upward enables the sensor again.
Application Example:
Typical parameter values for a 1380-2, appl. with electric defrost
P03 .......... -20
P07 .......... -15
P08 .......... -25
P09 .......... 2
P10 .......... 1
Dimensions / Wiring
Snap in
fixing
frame
from
rear
side.
mounting
TARN
Front frame
can be
removed
P11 .......... 2
P12 .......... -2
P13 .......... 1
P14 .......... 3
P22 .......... 14
P23 .......... 1
P24 .......... 060
P25 .......... 180
P28 .......... 30
P29 .......... 2
P30 .......... 1
P31 .......... 20
P32 .......... 7
P33 .......... -35
Airflow
Control
Sensor
Evaporator-
(Limit-)
sensor
lamella-
core
contact pipe
1 0
1
2
3
A C /D C
5
4
6
7
8
9
1 2 V
c o n tro l s e n s o r
c o ld s to ra g e
1 1 1 2
F 2
F 1
e v a p o ra to r-
(lim ita tio n )
s e n s o r
P
TAR
ELREHA
76 (3.0)
1/
2/
3/
4/
35 (1.38)
TAR
75 (2.95)
Rückansicht mit Befestigungsrahmen
rear view with mounting frame
37
(1
.4
6)
TARN
Rückansicht mit Befestigungsrahmen
75 (2.95)
rear view with mounting frame
37
(1
.4
6)
TAR
70 (
2.76
)
11
12
8
10
9
6
7
1
5
4
2
3
F1
Co
ld S
tor
ag
e C
on
tro
ller
Küh
lstell
enre
gler
E
LR
E
H
A
F2
AC/
DC
12 V
56 (2.2)
3 (.12)
28
(1
.1)
70 (
2.76
)
11
12
8
10
9
6
7
1
5
4
2
3
F1
Co
ld S
tor
ag
e C
on
tro
lle
r
Küh
lstell
enre
gler
E
LR
E
H
A
F2
230
V A
C
56 (2.2)
3 (.12)
70 (2.76)
28
(1
.1)
7 0 (2 .7 6 )
cu to u t
2 8 (1 .1 )
su p p lie d
g a ske t
10
9
8
6
7
P a n e l
3
5
4
1
2
set up: 11.4.17, tkd/jr
checked: 21.4.17, ek/ha approved: 21.4.17, mkt/mh
transl.(E):
transl()................ corr.: 9.6.17, tkd/jr