ELREHA TAR 1370-2 Manual Download Page 4

For the devices 

TAR 1370-2, TAR 1370-2 H, TAR 1380-2, TARN 1370-2, TARN 1380-2, TARN 21370-2, TARN 21380-2 we state the following: 

When operated in accordance with the technical manual, the criteria have been met that are outlined in the EMC Directive 

2014/30/EC and the Low Voltage 

Directive 

2014/35/EC. This declaration is valid for those products covered by the technical manual which itself is part of the declaration.

Following standards were consulted for the conformity testing to meet the requirements of EMC and Low Voltage Guidelines:

EN 55011:2016, EN 61010-1:2010, EN 61326-1:2013  

CE marking of year: 2017

This statement is made for the manufacturer / importer 

 

by: 

ELREHA Elektronische Regelungen GmbH 

 

Werner Roemer,

Technical Director 

D-68766 Hockenheim

 

    

www.elreha.de  

Hockenheim

......

10.4.2017

.......................................................................

(

Name / Address

)

C

ity                              Date

          S

ignature

EC Declaration of Conformity

  Installation / Start-Up

Sensor locations

Control Sensor:  

In the airflow, at the suction side of the evaporator.

Limit Sensor: 

In the lamella core or the contact pipe of the evaporator, 

at the place ice remains the longest time.

Applications with Airflow-Defrost

With this defrost method, there is no need for a defrost sensor in the 

evaporator, so the sensor can be disabled. If the correction parameter 

P20 is set to -10,1, the display shows "oFF" and the sensor is disabled. 

Correcting the parameter upward enables the sensor again. 

Application Example:

Typical parameter values for a 1380-2, appl. with electric defrost

P03 .......... -20  

P07 .......... -15

P08 .......... -25

P09 .......... 2

P10 .......... 1 

Dimensions / Wiring

Snap in

fixing 

frame 

from 

rear 

side.

mounting

TARN

Front frame 

can be 

removed

P11 .......... 2 

P12 .......... -2 

P13 .......... 1 

P14 .......... 3 

P22 .......... 14

P23 .......... 1

P24 .......... 060

P25 .......... 180 

P28 .......... 30 

P29 .......... 2 

P30 .......... 1

P31 .......... 20 

P32 .......... 7 

P33 .......... -35

Airflow

Control

Sensor

Evaporator-

(Limit-)

sensor

lamella-

core

contact pipe

1 0

1

2

3

A C /D C

5

4

6

7

8

9

1 2  V

c o n tro l s e n s o r

c o ld  s to ra g e

1 1 1 2

F 2

F 1

e v a p o ra to r-

(lim ita tio n )

s e n s o r

P

TAR

ELREHA

76 (3.0)

1/

2/

3/

4/

35 (1.38)

TAR

75 (2.95)

Rückansicht mit Befestigungsrahmen

rear view with mounting frame

37

 (1

.4

6)

TARN

Rückansicht mit Befestigungsrahmen

75 (2.95)

rear view with mounting frame

37

 (1

.4

6)

TAR

70 (

2.76

)

11
12

8

10

9

6
7

1

5

4

2
3

F1

Co

ld S
tor

ag

e C

on

tro

ller

Küh
lstell
enre
gler

E

LR

E

H

A

F2

AC/

DC

12 V

56 (2.2)

3 (.12)

28

 (1

.1)

70 (

2.76

)

11
12

8

10

9

6
7

1

5

4

2
3

F1

Co

ld S

tor

ag

e C

on

tro

lle

r

Küh
lstell
enre
gler

E

LR

E

H

A

F2

230

V A

C

56 (2.2)

3 (.12)

70 (2.76)

28

 (1

.1)

7 0  (2 .7 6 )

cu to u t

2 8  (1 .1 )

su p p lie d

g a ske t

10

9

8

6
7

P a n e l

3

5

4

1
2

set up:  11.4.17, tkd/jr 

checked:  21.4.17, ek/ha  approved: 21.4.17, mkt/mh  

transl.(E):  

transl()................  corr.:  9.6.17, tkd/jr

Reviews: