![ELPRO DVIPRO1000 Manual Download Page 38](http://html1.mh-extra.com/html/elpro/dvipro1000/dvipro1000_manual_2396041038.webp)
DVIPRO1000
8x2 UNIVERSAL SCALER MATRIX SWITCHER
& EFFECT CONTROL
38
ELPRO Video Labs s.r.l.
St.da della Pronda, 45/B 10142 Torino ITALY
Tel.+39 0117701583 – Fax +39 011703751
38
38
Es6: recall of preset number 6
The host must send the following sequence:
X 0 R 6 followed by CR
which in hexadecimal corresponds to:
58 30 52 36 0D
where “R” is the selection of the Recall function
6 is the selection of the preset to be recalled
The DVIPRO1000 replies:
ACK (06 hex) if the command has been recognized correctly
NACK (15 hex) if transmission errors have occurred
BEL (07 hex) when the command has been performed completely
Es7: reading of the Fade time of output channel 1
The host must send the following sequence:
R F 1 followed by CR
which in hexadecimal corresponds to:
52 46 31 0D
where “F” is the selection of the Tfade parameter
1 is the selection of output channel concerned
The DVIPRO1000 replies:
3 CR
which in hexadecimal corresponds to:
33 0D where 3 is the value of the Tfade parameter
Es8: reading of the position of the main window of channel 2
The host must send the following sequence:
R S 2 1 followed by CR
which in hexadecimal corresponds to:
52 53 32 31 0D
where “S” is the selection of size data
2 is the selection of the output channel concerned
1 is the selection of the Main window