background image

11 

CS2500 | INSTRUCTIONS FOR USE

10. Technical specification 

    

CS2500 is an integrated electro hydraulic crimp station, foot pedal operated. 

 

Hydraulic pressure range 

programmable within 0-700 bar

Crimp force 

self-adjusting in two steps, low and high

 

Max crimp force, 260 kN with 700 bar

Oil flow 

1.2 l/min (at 20 bar)

Oil volume 

1.0 l

Oil type 

HYDREX MV 22 (hydraulic oil mineral type) or simular

Dimensions, pump unit 

370 x 170 x 280 mm

Weight, pump unit 

11.5 kg 

Dimensions, crimp unit 

200 x 350 x 340

Weight, crimp unit 

59.5 kg

Mains unit pump 

85-276 VAC 50/60Hz / 24-28 VDC 30A; over current and over    

 

voltage protected; mains cord 4.5 m

Control module 

Elpress Advanced electronic, with display and key board, USB    

 port 

for PC-connection

Environment temperatures 

-15 to 40 °C

Protection 

IP 54

Hydraulic hose 

1.8 m with quick coupling

Controls 

Foot pedal, double switch model

CE-requirements met  

Machine safety 2006/42/EG, 

 

Electro magnetic compatibility 2014/30/EU

 

Low voltage directive 2014/35/EU

 

ROHS 2011/65/EU

 

WEEE 2012/19/EU

Accessories 

Elpress ANALYZER

, software for PC incl. USB cable and 

 

manual.

  
 

Summary of Contents for 7393487041202

Page 1: ...CS2500 Instructions for use GB...

Page 2: ...2 CS2500 INSTRUCTIONS FOR USE...

Page 3: ...CTION CERTIFICATE 4 2 ASSISTANCE 4 3 PERSONAL SAFETY 5 4 GENERAL DESCRIPTION 6 5 CS2500 SYSTEM COMPONENTS 7 6 USE OF CS2500 8 7 DISPLAY MENU 9 8 MAINTENANCE 10 9 ENVIRONMENTAL ASPECTS 10 10 TECHNICAL...

Page 4: ...urrent routines within Elpress and in correspondence with the relevant requirements in ISO 9001 2000 Inspection records are filed with Elpress and are available upon request Inspection date Inspector...

Page 5: ...ise risks always use protective glasses when operating Always check equipment before use with special regards to damage on the hose control cable and mains cable If damage is seen or suspected the uni...

Page 6: ...as well as the pressure build up of each crimp cycle are continuously monitored and logged into the electronic control module Most of the information can be directly read on the display after each cr...

Page 7: ...TIONS FOR USE 5 CS2500 System components Crimp station CS2500 Pump PS710D Foot pedal PC Software for crimp analysis and quality process integration Display Footpedal connection CAN bus system Hydrauli...

Page 8: ...e foot pedal switch is kept down the pump starts and hydraulic pressure is built up When pressure exceeds 15 bar the green LED flashes at about 4 Hz and the display shows press active This is starting...

Page 9: ...display By using the down switch on the keypad thid information is easy reached If any of the parameters above press time pressure current voltage oil temp or motor temp is out of preset limits there...

Page 10: ...tion When not in use main switch should be turned off and mains power plug disconnected All material in the CS2500 crimp station equipment fulfil ROHS demands and are recyclable Electrical equipment s...

Page 11: ...nit 11 5 kg Dimensions crimp unit 200 x 350 x 340 Weight crimp unit 59 5 kg Mains unit pump 85 276 VAC 50 60Hz 24 28 VDC 30A over current and over voltage protected mains cord 4 5 m Control module Elp...

Page 12: ...TSERKL RING TODISTUS SLANDARDINMUKAISUUDESTA DECLARATION OF CONFORMITY KONFORMIT TSERKL RUNG KONFORMITEITSVERKLARING D CLARATION DE CONFORMIT DECLARACI N DE CONFORMIDAD DECLARA O DE CONFIRMADADE DICHI...

Page 13: ...13 CS2500 INSTRUCTIONS FOR USE 11 Declaration of conformity...

Page 14: ...14 CS2500 INSTRUCTIONS FOR USE...

Page 15: ...15 CS2500 INSTRUCTIONS FOR USE...

Page 16: ...16 CS2500 INSTRUCTIONS FOR USE 8052 050500 Elpress AB P O Box 186 SE 872 24 KRAMFORS Sweden Tel 46 0 612 71 71 00 Fax 0 46 612 71 71 51 E mail sales elpress se www elpress net...

Reviews: