2. TURBO mode
– the timer is set for heating with the maximum set value of 34°C for a time specified by the
user.
To enter the TURBO mode, press the WEEK/TURBO/OK button and hold for 4s until the ‘0h’ setpoint ap
-
pears. Pressing the WEEK/TURBO/OK button repeatedly changes the setting to 1h, 2h, 3h (hours) and OFF.
After selecting the required setting, release the WEEK/TURBO/OK button (do not press anything else), wait
for 2s and after this time the timer will save the TURBO mode setpoint and the set duration. If you correctly
enable the TURBO mode, the dot in the third display segment will start flashing.
To enable the TURBO function you can:
•
Press the WEEK/TURBO/OK button and hold for 4s and then select the OFF option, release the WEEK/
TURBO/OK button and wait for 2s. The timer will exit the TURBO function.
•
Enter the NIGHT function settings (see below).
•
Reset the timer by disconnecting the power supply, i.e. setting the main switch (0-1) to ‘0’.
After the TURBO function has been disabled, the timer goes to the last active function (the WEEK function, if
it was used, or the NORMAL mode, if the WEEK function was disabled).
The TURBO mode has a higher priority (temperature adjustment) than the WEEK function!
3. NIGHT mode (economy mode)
– the timer is set for heating with a temperature that is 3°C (fixed value)
lower than the previously set temperature in the normal operation mode and for the user-specified duration.
To enter the NIGHT mode, press the NIGHT/OK button and hold for 4s until the setpoint ‘0h’ appears. Press
-
ing the MIGHT/OK button repeatedly changes the setting to 1h…9h and OFF. After selecting the desired du
-
ration of the NIGHT mode release the NIGHT/OK button (do not press anything else), wait for 2s, and then the
timer will enable the NIGHT mode for the set time. Correct activation of the NIGHT mode is signalled with a
flashing dot in the first display segment.
To disable the NIGHT function you can:
•
Press the NIGHT/OK button and hold for 4s and then select the OFF option, release the NIGHT/OK button
and wait for 2s. The timer will exit the NIGHT function.
•
Enter the TURBO function settings (see above).
•
Reset the timer by disconnecting the power supply, i.e. setting the main switch (0-1) to ‘0’.
After the NIGHT function has been disabled, the timer goes to the last active function (the WEEK function, if
it was used, or the NORMAL mode, if the WEEK function was disabled).
The NIGHT mode has a higher priority (temperature adjustment) than the WEEK function!
4. SAFE and CHILD functions
– these functions are intended to protect the radiator from overheating of the
heating surface above a temperature of 70°C and 50°C, respectively. In order to achieve it, the radiator works
(provided that all the conditions for switching on the heating are met) in cycles:
•
15s heating, 45s pause for the SAFE function;
•
10s heating, 50s pause for the CHILD function.
Additionally, the heating element will be disconnected if the radiator sensor (measurement at an appropriate
point outside the heating surface) makes a temperature measurement equal to or greater than:
•
58°C for the SAFE function (heating restarts at 55˚C);
•
38°C for the CHILD function (heating restarts at 35˚C).
The corresponding values for the heating surface are:
•
64˚C for the SAFE function (heating restarts at heating surface temperature 61˚C);
•