background image

 

Photoelectric Beam Detector 

EL-PB60 S 

 

9. Troubleshooting 

Symptom Possible 

cause 

Remedy 

LED does not 
light 

- No power supply 

- Turn on the power 

- Bad wiring connection or broken wire, short 

- Check wiring 

Alarm LED does 
not light when 
the beam is 
broken 

- No power supply 

- Turn on the power 

- Bad wiring connection or broken wire, short 

- Check wiring 

- Beam is reflected on another object and sent 
into the receiver 

- Remove the reflecting object or 
change beam direction 

- Two beams are not broken simultaneously 

- Break two beams simultaneously 

Alarm LED 
continues to light 

- Beam alignment is out 

- Check and adjust again 

- Shading object between Tx. and Rx. 

- Remove the shading object 

- Optics of unit are solied 

- Clean the optics with soft cloth 

Intermittent 
alarms 

- Bad wiring connection 

- Check again 

- change of supply voltage 

- Stabilize supply voltage 

- Shading object between Tx. and Rx. 

- Remove the shading object 

- A large electric noise source, such as power 
machine, is located nearby Tx. and Rx. 

- Change the place for installation 

- Unstable installation of Tx. and Rx. 

- Stabilize 

- Solied optics of Tx. and Rx. 

- Clean the optics with a soft cloth 

- Improper alignment 

- Check and adjust again 

- Small animals may pass through the 2 beams  - Set the response time longer 

 

 

10. Dimensions 
 
 
 
 
 
 
 
 
 
 

Limited Warranty 

elock Products are warranted to be free from detect in material and workmanship for 12 months from original date 

o shipment. Our warranty does not cover damage or failure caused by Acts of God, abuse, misuse, abnormal 

usage, faulty installation, improper maintenance or any repair other than those provided by elock, including implied 

warranties for merchantability and implied warranties for fitness are limited in duration to 12 months from original 

date of shipment. During the warranty period

, elock will repair or 

replace, at its sole option, free of charge, any 

defective parts returned prepaid. Please provide the model number of product, original date of shipment and 

nature of difficulty being experienced. There will render for product repairs made after our warranty period has 

expired. 

 

 

Summary of Contents for EL-PB60S

Page 1: ...25VDC Non polarity Current Max 57mA LED Tx Power Green LED Rx Sensitivity good Green LED When an alarm is initiated Red LED Alarm output Dry contact relay output form C Contact action Interruption time delay time 1 3 sec Contact capacity 30V AC DC 1A or Less Tamper output Dry contact relay output form N C Rx only Contact action Activated when cover is detached Contact capacity 30V AC DC 1A or Less...

Page 2: ...e visibility ran ace fog occ lation m Detec nstructio ur photoelec installed P gned to dete sponsible fo by lightening tector is dam tector may b r or replace ge or possi ur frequent ctor on ctric beam d Please read ect intrusion or damage g abuse m maged if it i be damaged e any parts ble distance ly detector Th this Instruc n and to init injury or los misuse abn s connected d if the app e can se...

Page 3: ...P 2 3 4 Photoe Part Des Respons Expansio electric cription se Time on of Beam c Beam m and Posit m Detec tion of Inst ctor tallation E EL PB60 S ...

Page 4: ...ic Beam Detector EL PB60 S 5 Installation 6 Channel Setting This function is used for purpose of preventing cross talk or bypass of beams which may occur in line protection or 2 stacked protection Set beam channel ...

Page 5: ...m Detec k with volt m r detached recover lens r on both si Using the a g the unit to r on the view horizontally and verticall ctor meter digita s by the vie ide and line adjuster the work in all w finder of i y and vertic ly to get hig l to confirm w finder e up optics h e lens can m the directio nside middl cally to get h ghest voltag m optical alig horizontally move horizo ons The op le mirror h...

Page 6: ... as power machine is located nearby Tx and Rx Change the place for installation Unstable installation of Tx and Rx Stabilize Solied optics of Tx and Rx Clean the optics with a soft cloth Improper alignment Check and adjust again Small animals may pass through the 2 beams Set the response time longer 10 Dimensions Limited Warranty elock Products are warranted to be free from detect in material and ...

Reviews: