Auto Gate System 

EL-EX5A 

 

 

Induction motor (AC) 

13, 14

  

Optional terminals for the motor’s capacitor.

 

15, 16, 17 

  Connect to induction motor (1 HP max); terminal 17 is the common point. 

 

 

Automatic lighting 

18

    

Output is 230VAC. It is always on whenever the gate is opened fully or partially. 

It will be off after it is closed shut. If there is a manual switch to it, ensure same power phase is 

used. 

 

 

Main Power Supply 

19, 20 

Terminal 20 is the Live input and terminal 19 is the Neutral point. This connection must be 

 

 

followed if pillar lighting is used. Nominal mains power is 230VAC, 50Hz 

 

 

Auto close function 

P3 

 

 Auto close is cancelled if jumper is set at NO position. If set to YES position, the gate will 

automatically start to close in 30 seconds after it has opened fully. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EL-EX5A

Page 1: ...to sensor Dual lighting mode control Follow or delay selectable Led indications for easy installation and fault diagnosis Photo Electric beam control input available Adjustable forcing sensing trimmer...

Page 2: ...The main shaft of the motor rotates the worm by the clutch the worm rotates the worm gear and output gears which push the racks attached to the sliding gates thus makes the gates slide The structure o...

Page 3: ...ighten the gear clutch Adjust the magnetic switch to the proper position by moving the gate with the motor he switch box be within 15 to 20 mm from the magnetic steel If too far away the switch would...

Page 4: ...move the gate friction clutch The pressure on friction clutch too small Increase the pressure by adjusting the pressure screw Motor stops when sliding gates are blocked friction clutch The pressure on...

Page 5: ...Auto Gate System EL EX5A...

Page 6: ...Auto Gate System EL EX5A Electrical Connection...

Page 7: ...osing and opening dynamic force adjustment Tuning VR2 clockwise for more sensitive reaction During closing gate reverses if overload occurred During opening gate stops if overload occurred Photobeam o...

Page 8: ...t will be off after it is closed shut If there is a manual switch to it ensure same power phase is used Main Power Supply 19 20 Terminal 20 is the Live input and terminal 19 is the Neutral point This...

Page 9: ...Auto Gate System EL EX5A Arrangement of The Electrical Installation...

Reviews: