Auto Gate System 

EL-EX5A 

 

Installation and adjustment 

 

The gate operator and the sliding gates should be installed according to Fig. 4, and controlled by button 

controller. To ensure the safety, it is highly recommended to install a limit device to prevent the gate sliding out 

of the rails. The rails must be installed horizontally and straight. 

 

Installation of the gate operator 

The foundation of the gate operator is shown in Fig. 5 and the position between the gate operator and the 

sliding gate is shown in Fig. 6. When the cements solidified, put the gate operator on the base plate and press 

it in the direction as shown in Fig. 6. Adjust it to the proper position and fix it with screws and nuts. 

 

Installation of racks: 

-  Weld the fixing shaft (inside the racks package) to the gate; 

-  Fix the racks to the fixing shaft with screws and adjust the position of the racks so that the   racks can be 

engaged correctly with gear and the allowance is 1 mm. 

-  Install the magnetic switch as shown in Fig. 6 and 7. A magnetic sensitive switch is installed to control the 

positions of the gates. When the switch is installed, release the gear clutch and push the sliding gates 

manually to pre determine the position. Then weld the magnetic fixed plate to the racks and lighten the gear 

clutch. Adjust the magnetic switch to the proper position by moving the gate with the motor. he switch box be 

within 15 to 20 mm from the magnetic steel. If too far away, the switch would fail to work. (See Fig. 6) 

 

Installation of Electric Controller 

Place the electric controller in the proper position and wire the lines according to the wiring scheme. (See Fig. 8) 

 

Operation 

 

Check whether there is cooling oil (filled before shipping) before using the operator. Refill the transformer oil 

NO. 25 it the oil is below the marked line. Cover the oil tank after refill but riot too lightly in case the oil, when 

heated and pressured, would produce leakage. 

 

Check the power supply and grounding and wiring before using the operator. 

 

Release the gear clutch with the special key to make sure whether the gates can be moved manually. If 

everything goes smoothly, tighten back the clutch with the key. 

 

Switch on the power and start the operator to watch whether the gates slide smoothly.

 

 

Adjust the position of the magnetic switch until the positions of the opening and closing meet the requirement. 

 

Adjust the pressure screw to make the output of the gate operator 

meet the user’s requirement, that is, the 

device is powerful enough to move the gates and capable of release from the clutch when it is blocked. 

 

The special motor of the operator is only designed to work for shot time. It is runs continually for a long time, it 

would stop work for too hot. 

Summary of Contents for EL-EX5A

Page 1: ...to sensor Dual lighting mode control Follow or delay selectable Led indications for easy installation and fault diagnosis Photo Electric beam control input available Adjustable forcing sensing trimmer...

Page 2: ...The main shaft of the motor rotates the worm by the clutch the worm rotates the worm gear and output gears which push the racks attached to the sliding gates thus makes the gates slide The structure o...

Page 3: ...ighten the gear clutch Adjust the magnetic switch to the proper position by moving the gate with the motor he switch box be within 15 to 20 mm from the magnetic steel If too far away the switch would...

Page 4: ...move the gate friction clutch The pressure on friction clutch too small Increase the pressure by adjusting the pressure screw Motor stops when sliding gates are blocked friction clutch The pressure on...

Page 5: ...Auto Gate System EL EX5A...

Page 6: ...Auto Gate System EL EX5A Electrical Connection...

Page 7: ...osing and opening dynamic force adjustment Tuning VR2 clockwise for more sensitive reaction During closing gate reverses if overload occurred During opening gate stops if overload occurred Photobeam o...

Page 8: ...t will be off after it is closed shut If there is a manual switch to it ensure same power phase is used Main Power Supply 19 20 Terminal 20 is the Live input and terminal 19 is the Neutral point This...

Page 9: ...Auto Gate System EL EX5A Arrangement of The Electrical Installation...