Art.-Nr./Art. No./Réf./N° art/N° art.: 9010002B01M
Version:
1.1
Date:
11.04.2016
3/1
1
165MSK...
- Only M4 flat head screws (e.g. M4 cylinder head screws ISO 4762) may be
used for mounting the safety sensor and actuator. Max. tightening torque
0.7 Nm. Screws made from non-ferromagnetic material (e.g. brass) must be
used.
- The safety sensor may only be mounted on an even surface as failure to do
so may lead to tension which could damage the safety sensor or alter the
switching distances.
- The connection cable of the safety sensor must be protected against
mechanical damage.
- During the assembly process, the requirements according to EN 14119
should be taken into consideration.
- Consider the requirements of EN 60204-1 when mounting, in particular with
regard to appropriate laying. It is recommended to conceal the safety sensor
lead.
10 Adjustment
- Always test the correct functionality with one of the approved safety control
units.
- The specified switching distances (see Technical specifications from
page 14) only apply for mounting on non-ferromagnetic material if the safety
sensor and actuator are mounted in parallel and facing each other. Other
layouts may lead to deviating switching distances.
11 Electrical connection
- Electrical connection is permitted in voltage-free state only.
- Connect the safety sensor according to the specified wire colours or pin
assignment (see Technical specifications from page 14).
- Please ensure that the voltage does not fall below the required minimum
input voltage of the downstream safety processing unit. For that reason
observe the voltage drop at the safety sensor (series resistor) and in the
connection cable.
- The voltage drop for the internal LED circuit is to be considered additionally
for LED safety sensors (see Technical specifications).
- For series connection of the safety sensors (verify approval in advance) their
respective NO paths must be connected in series and the respective NC
paths must be connected in parallel.
12 Commissioning
When commissioning, the following points must be ensured in advance:
- The safety sensor and actuator are positioned correctly and mounted in a
fixed position.
- The supply line is intact.
- There are no iron filings on the safety sensor and actuator.
The safety sensor and the connected control unit must then be tested for correct
functionality.
13 Maintenance
If the safety sensor is mounted and used correctly, no maintenance measures
are be necessary.
We recommend a visual and functional inspection carried out at regular
intervals:
- Check that the safety sensor and actuator are firmly seated.
To secure the mounting screws against easy disassembly, we
recommend using the screw covers included.
For safety sensors with connection plugs, suitable cable sets and
connectors for assembly are directly available from elobau (see
Technical specifications from page 14).
The control contact is not a safety contact.
It may not be incorporated into a safety circuit.
Use the control contact for non safety-relevant signal and control
functions only.
If several safety sensors with LED are used, the brightness of the
LEDs can decrease with an increasing number of closed safety
doors.
14 Dismantling
The safety sensor may only be dismantled in a voltage-free state.
15 Disposal
Dispose of packaging and used parts in accordance with the regulations of the
country in which the device is installed.
16 Information on the manufacturing date
The manufacturing date can be seen on the safety sensor casing
in the form of "week/year":
e.g. 37/14 = week 37/ year 2014