background image

Elnur

 

powered by Gabarrón  |  RXE PLUS  |   Installation Guide

8

OPEN WINDOW DETECTION

With open window detection activated, the heating 

element will be disconnected automatically when a 

sharp decrease in temperature in the room is detected 

avoiding energy wastage. After this period of time,  

the radiator returns to the prior operation mode.
When Open Window Detection is working, the word 

Open will be displayed alternating with the status  

of the current mode.
Note: To activate the open window detection please 

refer to ADVANCED FUNCTION ACTIVATION section.

ADAPTIVE START CONTROL

RFE Plus electronic control analyses the heating 

requirements of the room where the radiator is installed 

using this information to turn on the heating element in 

advance in order to reach the set point temperature at 

the desired time.
When Adaptive Start Control is working, the word AdAP 

will be displayed alternating with the status of the  

current mode.

Note

: To activate the adaptive start control please refer 

to ADVANCED FUNCTION ACTIVATION section.

ADVANCED FUNCTION ACTIVATION

Advanced functions Open Windows Detection and 

Adaptive Start Control are disabled by default.  

To enable / disable these functions, the following  

steps must be followed:
Move the selector to 

0

 position, the display will be Off. 

Press the 

     

key and at the same time turn the selector 

to 

P

  position maintaining the 

     

key at least five 

seconds.

The display will show  

OPEN

  alternating with the status 

of the function (On or OFF). Use the navigation keys + or 
– to enable / disable Open Windows Detection function.
Confirm the new value for the function by pressing the 

PRG

 key. The next function (AdAP) is shown alternating 

with its status (On or OFF). Use the navigation keys + 

or – to enable / disable Adaptive Start Control function. 

Confirm the new value for the function by pressing the 

PRG

 key.

The heater reset establishes the factory configuration 
of the heater removing the programming, establishing 
the daily programming and disabling the advanced 
functions. To reset the unit, hold the 

PRG

 key for 4 

seconds, the display will show  

 InIC

   to indicate the 

heater has been reset.

6: CLEANING AND MAINTENANCE 

The radiators do not require any special maintenance 

providing thermal comfort during large periods.  

Clean dust with a dry, soft cloth only when the unit  

is disconnected and cold.
Do not use solvents or abrasive products for cleaning.
This thermal radiator has been manufactured under 

an assured quality system using environment friendly 

processes.
Please take the heaters to a clean point once their 

useful life is finished, in order to recycle their materials 

in the right way.

4: ADVANCED FUNCTION 

5: UNIT RESET

Summary of Contents for RX10E Plus

Page 1: ...ese instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide RXE PLUS Thermal Radiators RX4E Plus RX6E Plus RX8E Plus RX10E Plus RX12E P...

Page 2: ...ial that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the curren...

Page 3: ...screws to attach the supports are in the accessories bag Hang the unit on the hooks of the brackets By turning the screws the metallic square will go downwards retaining the heater Repeat this on the...

Page 4: ...ital DISPLAY It shows the time temperature and other messages Heating indicator This small dot will be lit when the heater is consuming energy Frost protection key If the display shows the time the he...

Page 5: ...standard mode temperature is shown in the display and vice versa The electronic programmer is able to handle three temperature levels during a 24hr period Press the key to set the SUN temperature The...

Page 6: ...dify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be used also to store th...

Page 7: ...y pressing key If the display shows day1 then pressing and holding the key will copy the day 1 program to day 2 and so on It is possible to allocate any of the three temperature levels to all of the i...

Page 8: ...Move the selector to 0 position the display will be Off Press the key and at the same time turn the selector to P position maintaining the key at least five seconds The display will show OPEN alterna...

Page 9: ...e Only daily programmes The controller is in single 24hr mode factory default See WEEKLY PROGRAMMES section to switch to 24hr 7days mode The keyboard does not respond If the display shows the keyboard...

Page 10: ...Elnur powered by Gabarr n RXE PLUS Installation Guide 10 10 WIRING R heating element Ts safety cut out C three way selector...

Page 11: ...t output el min 0 000 0 000 0 000 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 0 0005 0 0005 0 0005 kW MODEL S GABARRON RX4E Plus RX6E Plus RX8E Plus RX10E Plus RX12E Plus RX14E Plu...

Page 12: ...ay not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of...

Reviews: