Turn the mode selector dial to P position then press  
and hold the        until the time flashes intermittently.  
Set the hours by pressing the + and – keys. Set the 
minutes the same way. Press the        key once more  
to store the time. 
If at any point you should need to change the times 
that have been set, just press the        key and repeat 
the above process.
 

FROST PROTECTION MODE

With this mode on, if the room temperature drops  

below 3oC the heater will connect itself automatically.
If the display shows the time, the heater is in frost 
protection mode. Press the        key to shift from frost 

protection mode (time is shown in the display) to 

standard mode (temperature is shown in the display) 

and vice versa.

SELECTOR “O”, “P”, “I”. 

Position “0”: 

    

The heater is switched off permanently. The display  
is switched off.

Position “P”:

 

 

The heater is following a program. It will maintain the 
SUN, MOON or        temperatures as per the introduced 
program. At this position if the display shows the time 
the heater is in frost protection mode.

Position “I”:

 

 

The heater is maintaining the SUN temperature and  
will be identified by both the SUN and MOON indicator 
being lit. This is useful when the SUN temperature is 
required, and we do not want to modify the program.  
At this position, if the display shows the time the 
heater is in frost protection mode. Press the        key to 
shift from frost protection mode (time is shown in the 
display) to standard mode (temperature is shown in  
the display) and vice versa.

The electronic programmer is able to handle three 
temperature levels during a 24hr period.
Press the        key to set the SUN temperature.  
The display will show the SUN temperature. The display 
will show the SUN temperature value blinking.
Set the SUN temperature value by means of the + and 
– keys and press the        key to store the value. If the 
display shows the time the heater is in frost protection 
mode. Press the        key to shift from frost protection 
mode (time is shown in the display) to standard mode 
(temperature is shown in the display) and vice versa.
Repeat the above steps with the        key to set the 
MOON temperature.
The        temperature level is 3oC and it is a fixed value.
SUN, MOON or        temperatures can be allocated to any 
of the 48 intervals of 30 minutes throughout the day.

DAILY PROGRAMMES

It is best to visualise the day split in to 48 intervals of  
30 minutes each. The SUN, MOON or        temperatures 
can be allocated to any of them.
The default settings include a daily mode so that the 
heater will repeat the program every day. If different 
programmes are required throughout the week, please 
see the next step WEEKLY PROGRAMMES. To check a 
programme or to make a new one, follow these steps:

Press the ‘PRG’ key and the display will show 00:00 
intermittently.
Press one of the three keys –                       to allocate 
SUN, MOON or OFF (frost protection) from 00:00h to 
00:30h. If SUN or MOON temperatures are selected  
the relevant luminous indicator will be lit.  
If OFF temperature        is selected both luminous 
indicators will be off.

SWITCHING ON THE HEATER  

AND SETTING THE TIME 

SUN, MOON AND      

TEMPERATURES 

Summary of Contents for RX10E Plus

Page 1: ...ese instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide RXE PLUS Thermal Radiators RX4E Plus RX6E Plus RX8E Plus RX10E Plus RX12E P...

Page 2: ...ial that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the curren...

Page 3: ...screws to attach the supports are in the accessories bag Hang the unit on the hooks of the brackets By turning the screws the metallic square will go downwards retaining the heater Repeat this on the...

Page 4: ...ital DISPLAY It shows the time temperature and other messages Heating indicator This small dot will be lit when the heater is consuming energy Frost protection key If the display shows the time the he...

Page 5: ...standard mode temperature is shown in the display and vice versa The electronic programmer is able to handle three temperature levels during a 24hr period Press the key to set the SUN temperature The...

Page 6: ...dify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be used also to store th...

Page 7: ...y pressing key If the display shows day1 then pressing and holding the key will copy the day 1 program to day 2 and so on It is possible to allocate any of the three temperature levels to all of the i...

Page 8: ...Move the selector to 0 position the display will be Off Press the key and at the same time turn the selector to P position maintaining the key at least five seconds The display will show OPEN alterna...

Page 9: ...e Only daily programmes The controller is in single 24hr mode factory default See WEEKLY PROGRAMMES section to switch to 24hr 7days mode The keyboard does not respond If the display shows the keyboard...

Page 10: ...Elnur powered by Gabarr n RXE PLUS Installation Guide 10 10 WIRING R heating element Ts safety cut out C three way selector...

Page 11: ...t output el min 0 000 0 000 0 000 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 0 0005 0 0005 0 0005 kW MODEL S GABARRON RX4E Plus RX6E Plus RX8E Plus RX10E Plus RX12E Plus RX14E Plu...

Page 12: ...ay not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of...

Reviews: