Elnur
powered by Gabarrón | RXE PLUS | Installation Guide
5
Turn the mode selector dial to P position then press
and hold the until the time flashes intermittently.
Set the hours by pressing the + and – keys. Set the
minutes the same way. Press the key once more
to store the time.
If at any point you should need to change the times
that have been set, just press the key and repeat
the above process.
FROST PROTECTION MODE
With this mode on, if the room temperature drops
below 3oC the heater will connect itself automatically.
If the display shows the time, the heater is in frost
protection mode. Press the key to shift from frost
protection mode (time is shown in the display) to
standard mode (temperature is shown in the display)
and vice versa.
SELECTOR “O”, “P”, “I”.
Position “0”:
The heater is switched off permanently. The display
is switched off.
Position “P”:
The heater is following a program. It will maintain the
SUN, MOON or temperatures as per the introduced
program. At this position if the display shows the time
the heater is in frost protection mode.
Position “I”:
The heater is maintaining the SUN temperature and
will be identified by both the SUN and MOON indicator
being lit. This is useful when the SUN temperature is
required, and we do not want to modify the program.
At this position, if the display shows the time the
heater is in frost protection mode. Press the key to
shift from frost protection mode (time is shown in the
display) to standard mode (temperature is shown in
the display) and vice versa.
The electronic programmer is able to handle three
temperature levels during a 24hr period.
Press the key to set the SUN temperature.
The display will show the SUN temperature. The display
will show the SUN temperature value blinking.
Set the SUN temperature value by means of the + and
– keys and press the key to store the value. If the
display shows the time the heater is in frost protection
mode. Press the key to shift from frost protection
mode (time is shown in the display) to standard mode
(temperature is shown in the display) and vice versa.
Repeat the above steps with the key to set the
MOON temperature.
The temperature level is 3oC and it is a fixed value.
SUN, MOON or temperatures can be allocated to any
of the 48 intervals of 30 minutes throughout the day.
DAILY PROGRAMMES
It is best to visualise the day split in to 48 intervals of
30 minutes each. The SUN, MOON or temperatures
can be allocated to any of them.
The default settings include a daily mode so that the
heater will repeat the program every day. If different
programmes are required throughout the week, please
see the next step WEEKLY PROGRAMMES. To check a
programme or to make a new one, follow these steps:
Press the ‘PRG’ key and the display will show 00:00
intermittently.
Press one of the three keys – to allocate
SUN, MOON or OFF (frost protection) from 00:00h to
00:30h. If SUN or MOON temperatures are selected
the relevant luminous indicator will be lit.
If OFF temperature is selected both luminous
indicators will be off.
SWITCHING ON THE HEATER
AND SETTING THE TIME
SUN, MOON AND
TEMPERATURES