Elnur INTERTIARX10E Installation Instructions And User Manual Download Page 2

 

INSTALLATION INSTRUCTIONS

 

1.- WARNING

 

  The warranty of the heater will not cover any damage caused by non observance of any of these instructions. 

  The instructions should be retained for future reference. This guide must be kept and given to any new owner. 

  Please check that the voltage in the rating label fits the power supply. 

  Any reinstallation should be carried out by trained personnel. 

  The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. 

  DO NOT USE THIS HEATER TO DRY CLOTHES. 

  The surfaces of this heater can be hot, so young children should not be left unsupervised in the vicinity of the heater. 

  Children should be supervised to ensure they do not play with the appliance. 

  Neither the connecting cable nor any other object must come into contact with the hot unit. 

  Do not cover this heater at any time. 

  The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the appliance. 

They also protect the heater from overheating; therefore, it is essential that at no time are they covered. 

  This heater should be switched off at the isolating switch before any repair work is carried out. 

  The thermal radiator should not be installed just below an electrical socket. 

  The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls. 

  The installation must be carried out in accordance with the current electrical regulations. 

  The heater is fitted with a flexible cable size 3 x 1.00 mm

²

 for electrical connection. It may be used to connect the heater to the fixed wiring of the 

premised through a suitable connection box positioned adjacent to the heater.  

  The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm. 

  If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special tools 

are necessary. 

  This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, 

unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. 

  This appliance must be earthed.

 

 

  The infrared heater is designed to only work in a horizontal position. 

  All  models  are  supplied  with  an  electrical  interrupt  cut-out.  This  will  switch  off  the  heater  if,  for  any  reason,  it  overheats.  Should  the  cut-out 

operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically. 

  The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater. 

 

MODELS 

RX4P 
RX4F 
RX4E 

RX6P 
RX6F 
RX6E 

RX8P 
RX8F 
RX8E 

RX10P 
RX10F 
RX10E 

RX12P 
RX12F 
RX12E 

MODULES 

10 

12 

W (cm) 

41.5 

57.5 

73.5 

89.5 

105.5 

D (cm) 

10 + 2 cm separated from the wall 

H (cm) 

58 

WEIGHT (kg) 

9,5 

13,5 

17,5 

21,5 

25,5 

VOLTAGE 

220-240V~ 

INPUT (W) 

500 

750 

1000 

1250 

1500 

 
 

2.- INSTRUCTIONS ON INSTALLATION 

 

 
- Open the carton at the indicated side. The screws are in the accessories bag. Turn the carton upside down to allow the heater to stand. Check 
that it is the correct model and that it is in good condition. 
- To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as 
furniture, curtains etc. See figure. 
 
 

 

 

 

 

 

 

 

 
 

 
 
 
 

 

shelf 

mínimum 15cm

 

Closest 
object to the 
right end 

mínimum 25cm 

mínimum 10cm 

Closest 

object to 

the left 

end 

minimum15cm 

Summary of Contents for INTERTIARX10E

Page 1: ...INTERTIA ELECTRIC RADIATOR RX4P RX6P RX8P RX10P RX12P RX14P RX4F RX6F RX8F RX10F RX12F RX14F RX4E RX6E RX8E RX10E RX12E RX14E Please read these instructions before installing or using this appliance...

Page 2: ...ble connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm If the flexible power...

Page 3: ...aintains the set temperature with the temperature selector dial Moon mode on the heater maintains a temperature 3 C lower than the one set with the temperature selector dial The studs and screws are i...

Page 4: ...ify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys The new set b...

Page 5: ...s frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is required and...

Page 6: ...d both luminous indicators will be off Press the key to go to the next interval The display will show 00 30 intermittently and again press one of the three keys T to allocate SUN MOON or OFF frost pro...

Page 7: ...six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller will keep on wo...

Page 8: ...8 WIRING MODELS RX P R heating element Ts safety cut out C three way selector MODELS RX F R heating element Ts safety cut out MODELS RX E R heating element Ts safety cut out C three way selector...

Page 9: ...d electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by i...

Page 10: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...

Reviews: