GENERAL OPERATION MENU
Accessing the general operation menu
It is possible to modify the general operation parameters,
such as charging configuration, temperature units and more.
During any operation mode from the main screen,
you can access the settings.
Hold the button until “Func” is displayed press
the button until
“PArA.” is displayed. Press to access the
general parameters menu. UP01 will be displayed.
Access to the parameter value
Change value: Decrease
Confirm value
Use and to move on through the different parameters.
Use to access the parameter you want to modify. Change
the value using the navigation keys and . Confirm the
new value with .
It is possible to save the changes and exit at any moment by
pressing . Ecombi SSH general parameters that can be
modified by the user are.
- UP01:
Initial % of storage charge.
- UP02:
Starting time of reduced (off-peak) rate electric period.
- UP03:
Ending time of reduced rate electric period.
- UP04:
Starting time of the second reduced rate electric period.
(if not available set up 00:00).
- UP05:
Ending time of the second reduced rate electric period.
(if not available set up 00:00).
- UP06:
Charging days during the week.
- UP07:
Temperature ambient sensor correction
(values from -5ºC to5ºC).
- UP08:
Maximum working period of the balancing heating
element in on peak electric period.
- UP09:
Excess of temperature protection during the charge,
Degrees higher than the comfort set point temperature
(Auto Mode) or the manual set point temperature
(Manual Mode) when the charge is interrupted.
(Values 1,2,3,4 & 5).
- UP10:
Degrees Celsius or Fahrenheit. (Values: ºC – F).
- UP11:
Open Window Detection Activation. (On/Off).
- UP12:
Adaptive Start Control Activation (On/Off)
- UP13:
Kind of temperature control. Recommended &
default PID.
ECOMBI SSH does not change automatically
from summer time to winter time or vice
versa when not connected to the internet.
Depending on the tariff it may be necessary
to change the clock settings to fit these
two timings.
i