27
SWITCHING REGULATOR UNIT
TO REMOVE:
1. Remove the front cover and the rear cover. (Refer to pages 6 and 7.)
2. Remove the setscrews (3 pcs.) and the switching regulator with cords.
TO ATTACH:
3. Follow the above procedures in reverse.
Be sure to connect the connectors (switching regulator connector (white) and ErP switch connector (Red)) to
the circuit board A (Refer to page 23).
* ErP switch (Red) is only for the applicable model.
REPLACING THE ELECTRONIC COMPONENTS
Switching
regulator
Setscrew
Setscrew
Setscrew