background image

27

Adjusting X and Y Sensors (Instant Adjustment)

To adjust X and Y sensor (without removing the base unit):

1 Remove the base cover.

2 Remove the presser foot holder and attach the

     Embroidery foop (A)      .

3 Turn the Power “ON” and select the Embroidery

     Mode, then press pattern No.1.

4 Turn the handwheel by hand to check that the

      Needle       drops into the Starting position      on

      the Template       .

5 Turn the Power “OFF”.

6 If the needle position shifts in Y direction, loosen Screw

      (A)       and move the Y sensor fixing plate       to

     adjust the needle drop position.

7 If the needle position shifts in X direction, loosen Screw

     “B”       through the sheet cover fixing plate hole and

      adjust the X shield plate possition       .

8 Turn the Power “ON” and select pattern No.1 on the

     Embroidery Mode, then check the Start position       .

9 Return the carriage to the home position and turn the

     Power “OFF”.

10. Remove the Template       and the Embroidery hoop

            , then reattach the base cover.

   Embroidery hoop (A)

   Template

   Marks

             Needle

             Start position

             Screw (B)

             X-shield plate

             Sheet cover fixing hole

             Screw (A)

             Y-Sensor fixing plate

10

8

6

7

3

2

1

4

5

6

9

1

5

4

2

9

10

6

7

5

2

1

1

2

3

4

5

6

7

8

9

10

Summary of Contents for CE10

Page 1: ...SERVICE MANUAL PARTS LIST CE10...

Page 2: ...Gear 12 Adjusting Upper Shaft Shield Plate Position 13 Adjusting Nedle Thread Tension 14 Adjusting Tension Release Mechanism for Knee Lifter 15 Changing Thread Tension Unit 16 Replacing Threader Plate...

Page 3: ...1 Face Cover To remove 1 Remove the Cap and Screw A and remove the Face Cover Cap Screw A Face cover To attach 2 Attach the Face Cover and tighten Screw A then attach the Cap Replacing the face cover...

Page 4: ...Screw A 2 Loosen Screw B and remove Screw C and D 3 Turn the machine to the back and remove Screws C and D then remove the Belt cover Cap Screw A Screw B Screw C Screw D Belt cover To attach 4 Attach...

Page 5: ...anging External Parts 3 Base Cover Replacing the base cover To remove 1 Remove Screws 4 pieces to remove the base cover Screw Base cover To attach 2 Follow the above procedure in reverse 1 2 1 1 2 1 1...

Page 6: ...ove the Base Lid 3 Remove Screw B 2 pcs and remove the Bed cover Screw A Base lid Screw B Bed cover To attach 4 Follow the above procedure in reverse Replacing base cap To remove 1 Remove Screws 4 pie...

Page 7: ...ccessory Screw B To attach 4 Attach the X Y Motor Connectors into the printed circuit board A 5 Insert the X Y Motor Cords between the printed cuircuit board A and Arm without touching the jointing po...

Page 8: ...D 5 Disconnect the each connector and remove the front cover Note Disconnect the Hooks while removing the Front cover Screw A Arm thread guide Lower Screw B Screw C Screw D Hooks 4 spots To attach 6...

Page 9: ...2 Loosen Screw A and B 3 Raise the handle and remove Screw C and Cap then remove Screw D Remove the Rear cover Screw A Screw B Carriage Screw C Rear cover Cap Screw D To attach 3 Follow the above proc...

Page 10: ...oosen Screw move the Needle bar supporter to the right or left until the needle comes to the center of the Needle plate hole 3 Tighten the Screw 4 Attach the face cover Screw Needle bar supporter Need...

Page 11: ...wheel toward you 4 Raise the needle bar further 3 1 to 3 7 mm from the lowest position 5 Loosen the screws of lower shaft gear turn the Lower shaft gear until the tip of rotary hook meets with the rig...

Page 12: ...in front of you and tighten Screw 7 Attach the Bobbin holder B Needle plate A presser foot and needle 8 Attach the face cover Needle plate A Bobbin holder B Screw Needle bar Groove Needle 14 Matching...

Page 13: ...pin and the Tip of rotary hook position to 0 10 to 0 05 mm by moving the rotary hook set plate up or down 4 Tighten the screws A B C firmly 5 Check the rotary hook driver gear and the lower shaft gear...

Page 14: ...rotary hook 1 Remove the base cover base lid and bed cover See page 3 4 2 Loosen the Hexagonal socket screw 3 A If the backlash is too big or too large turn the lower shaft bushing in the direction o...

Page 15: ...t shield plate in the direction of B 3 Place the right hand of the Upper shaft shield plate at the center position of the Upper shaft sensor and tighten Setcrew 4 Turn the handwheel toward you to chec...

Page 16: ...1 Set the Thread tension dial at 3 2 Lower the presser foot 3 Remove the front cover unit and adjust the thread tension A If the thread tension is 59g or more turn the screw in the direction of B B If...

Page 17: ...spring holder and tighten the Screw A 4 Raise the presser foot lifter turn the thread tension dial from 9 to 0 make sure the clearance between the tension discs should be 1 0 mm 5 Reattach the front c...

Page 18: ...ee page 6 2 Remove Setscrew A B and remove the thread tension dial To attach 3 Follow the above procedure in reverse Note After the replacement adjust Thread Tension Release Machanism and Adjustment o...

Page 19: ...sh it up to insert Threader supporter A Pin B Hook Adjusting threader plate position 1 When the hook is slightly touching the nedle eye loosen Screw C and adjust the Threader plate as shown If the hoo...

Page 20: ...front cover unit See page 6 2 Lower the needle bar and lower the presser foot lifter 3 Insert the 1 2 mm Thickness gauge between the Embroidery Foot P and the needle plate 4 While pressing the Pressu...

Page 21: ...4 10 6 7 8 9 Touch panel LCD Harness Printed circuit board F Black Bobbin winder sensor Blue Upper shaft sensor White Thread detectionsensor Red Presser foot lifter sensor Red 12 8 9 10 11 13 14 Switc...

Page 22: ...printed circuit board F LCD Harness Inverter and Touch panel 3 Remove screws 5 pieces and the Printed circuit board A To attach 4 Follow the above procedure in reverse To replace the printed circuit b...

Page 23: ...rom the Inverter 4 Remove Screws 4 pieces and remove the touch panel To attach 5 While butting the LCD to the ribs A B C spots butt the D and E of the LCD fixing plate bottom to the LCD and tighten sc...

Page 24: ...below Printed circuit board F To remove 1 Remove the front cover See page 6 2 Pull out the connectors from the printed circuit board A 3 Remove Screws 2 pieces and remove the Printed circuit board F T...

Page 25: ...Remove the front cover See page 6 2 Loosen Screws 2 pieces 3 Lower the presser foot lifter and adjust the Clearance between the Discs while the discs are closed 4 Tighten Screws 1 2 3 4 Screw A Discs...

Page 26: ...A 2 pieces temporarily and attach the motor 6 Adjust the motor belt tension and tighten screws A 2 pieces firmly Adjusting motor belt tension 1 Tighten screws B 2 pieces temporarily 2 Adjust the Belt...

Page 27: ...he Power ON and return the carriage to the home position 4 Remove Screws 3 pieces and remove the carriage plate To attach 5 Attach the carriage plate unit with tightening screws temporarily 6 After th...

Page 28: ...osition 2 Turn the Power OFF and then remove the base unit 3 Loosen Screw A to adjust dimension Y to moving the Y sensor attachinr plate 4 Loosen screw B to adjust Dimension X 1 to 69 0 mm and Dimensi...

Page 29: ...and move the Y sensor fixing plate to adjust the needle drop position 7 If the needle position shifts in X direction loosen Screw B through the sheet cover fixing plate hole and adjust the X shield p...

Page 30: ...the carriage movement 6 Insert a Piece of paper between the thread tension discs as shown so that the needle thread sensor will not work 7 Run the machine and loosen Screws B 2 pieces and move the X m...

Page 31: ...socket and fixing plate 3 Pull out the Machine socket unit connector 4 Remove screw C and remove the Idler 5 Remove Screws D 2 pieces and Switching power supply to the handwheel side To attach 6 Follo...