A.1 Technical Data
A.1.1 Power Supply
Supply voltage:
NC battery 6 V / 6 Ah
Pb battery 6 V / 6.5 Ah
Power consumption:
1 - 2 amperes
Test duration
During continuous operation:
approx. 3 hours
During cyclic operation:
approx. 9 hours
A.1.2 Test Voltage
Voltage form:
unipolar pulses
Pulse repetition period:
approx. 10 µs
Pulse repetition frequency:
30 Hz
Current (effective value):
approx. 40 mA
A.1.3 Dimensions and Weights
Length:
280 mm
Height:
235 mm
Width:
100 mm
Length of high-voltage cable:
1500 mm
Weight incl. handle:
4.5 kg
Weight of the battery:
1.0 kg