Technical Support: +44(0)23 9269 6638 (option 3) 

 

PAK200610_01G   Jan 2021        ©2019 ELMDENE INTERNATIONAL LTD  

 

C

OMPLIANCE

 

 

 

This power supply unit meets the essential requirements 
of the following EU Directives: 
EMC: 2014/30/EU 

Low Voltage: 2014/35/EU 

WEEE: 2012/19/EU  RoHS2: 2011/65/EU 

 

 
 
 
 
 
 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 
This product falls within the scope of EU Directives  2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EU  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 
 
Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries 
safely for onward transport to your supplier, collection point or disposal facility. 
 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 
See  Specification  for  battery  type  information.  The  battery  is  marked  with  the  crossed  out  wheelie  bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 
 

For more information see: 

www.recyclethis.info

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The packaging supplied with this product may be recycled. 

Please dispose of packaging accordingly.

 

0843 14 (UL) 

2531 20 (DBI)

 

Elmdene International Ltd 3 Keel 

Close Portsmouth PO35QD 

0843-CPR-0216 

2531-CPR-CSP11215 

EN54-4:1997 +A1 +A2 

Power Supplies intended for use in 

fire detection and fire alarm 

systems 

 

Operational reliability

                    

- Pass 

 

Durability 

 

 

 

Temperature resistance  

Pass 

Vibration resistance 

Pass 

Electrical stability 

Pass 

Humidity resistance 

Pass 

 
 

Summary of Contents for STX2410-MOD

Page 1: ...eriods Two sets of volt free solid state relay fault outputs signal i loss of mains and ii battery fault charger fault and loss of output In addition there is an RS232 serial interface that can provid...

Page 2: ...220V With charging Imax A 110V 10 0A 10 0A 8 5A 10 0A 8 0A 7 5A 10 0A 7 2A 6 5A Battery Capacity eg PowerSonic model Yuasa model Interlogix model 2 x 17 18Ah 12V PS12170 NP17 12 BS131N 2 x 38Ah 12V PS...

Page 3: ...s EPS Fault GEN Fault Condition Possible Cause Action CLOSED CLOSED Normal operation Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mai...

Page 4: ...n to manufacturer 5 PULSES ON or OFF Battery Temperature Probe Fault Battery temperature monitor disconnected or damaged PSU running in Safe Mode Check temperature sensor connections and condition of...

Page 5: ...at dissipation and adequate ventilation to avoid overheating of the unit or associated batteries Figure 1 Fixing points COMMISSIONING Mains Power Up 1 With no external connections made to the PSU conn...

Page 6: ...CT the other two battery terminals to each other 12 Connect the free Positive and Negative terminals of the batteries to the PCB terminals Batt and Batt using the cables provided See Figures 2 3 13 Co...

Page 7: ...r use by Service Personnel only There are NO USER SERVICEABLE parts inside There is no regular maintenance required of the PSU other than periodic testing and replacement of the standby battery Refere...

Page 8: ...proved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution Ri...

Reviews: