PECIFICATION

 

 

 

Mains Input 

Rated Voltage 

110 

 240V ac  

Frequency 

50/60 Hz 

Input current 

< 4.0 Amps at full load 

Inrush current 

30A Max at 25 °C 110V ac for 10 ms 

Fuse 

T4.0A, 20 mm, 250V ac HRC 

 
Output 

Voltage at full load 

 

Mains power 

 

Battery standby 

 
26.0 

 28.5V dc  (27.6 V nominal) 

18 

 26.0V dc  

Ripple 

<100 mV pk 

 pk max @ Rated Voltage 

Fuse 
 

Load 

 

Battery 

 

F10.0A 
F10.0A 

Overload 

Electronic shutdown at 15A until overload or short circuit removed

 

Battery mode selected 

18 Ah 

 

38 Ah

 

65 Ah

 

Continuous Output Current 

No charging (Imax B)  

With charging  (Imax A) 

 220V 

With charging (Imax A) 

 110V 

 

10.0A 
10.0A 

8.5A 

 

10.0A 

8.0A 
7.5A 

 

10.0A 

7.2A 
6.5A 

Battery Capacity 
eg 

-

 

PowerSonic model 

-

 

Yuasa model 

-

 

Interlogix model 

2 x 17/18Ah 12V 

 

PS12170 
NP17-12 

BS131N 

2 x 38Ah 12V 

 

PS12380 
NP38-12 

2 x 65Ah 12V 

 

PS12650 
NP65-12 

BS133N 

Battery Charging 

Constant current bulk charging to 80% capacity within 24 hours 
Float charging to 100% within 48 hours 
Eco charging and check every 2 hours 

 (for 20 minutes) 

Constant current charge 

0.7A 

1.6A 

2.6A 

Low battery threshold voltage 

23V 

Deep discharge protection 

Threshold voltage 

 21V 

Quiescent current 

 no load 

30 mA 

Quiescent current 

 batt cut off 

0 mA 

 

 

Mechanical 

Product Reference 

STX2410-MOD 

Module Dimensions 

245L x 135W x 60D

 

Weight (kg)

 excluding battery 

1.42 

 

Environmental  

Temperature 

 Operating 

-10 to +40°C (operating) 75% RH non-condensing 

Temperature - Storage 

-20 to +80°C (storage) 

 

Summary of Contents for STX2410-MOD

Page 1: ...eriods Two sets of volt free solid state relay fault outputs signal i loss of mains and ii battery fault charger fault and loss of output In addition there is an RS232 serial interface that can provid...

Page 2: ...220V With charging Imax A 110V 10 0A 10 0A 8 5A 10 0A 8 0A 7 5A 10 0A 7 2A 6 5A Battery Capacity eg PowerSonic model Yuasa model Interlogix model 2 x 17 18Ah 12V PS12170 NP17 12 BS131N 2 x 38Ah 12V PS...

Page 3: ...s EPS Fault GEN Fault Condition Possible Cause Action CLOSED CLOSED Normal operation Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mai...

Page 4: ...n to manufacturer 5 PULSES ON or OFF Battery Temperature Probe Fault Battery temperature monitor disconnected or damaged PSU running in Safe Mode Check temperature sensor connections and condition of...

Page 5: ...at dissipation and adequate ventilation to avoid overheating of the unit or associated batteries Figure 1 Fixing points COMMISSIONING Mains Power Up 1 With no external connections made to the PSU conn...

Page 6: ...CT the other two battery terminals to each other 12 Connect the free Positive and Negative terminals of the batteries to the PCB terminals Batt and Batt using the cables provided See Figures 2 3 13 Co...

Page 7: ...r use by Service Personnel only There are NO USER SERVICEABLE parts inside There is no regular maintenance required of the PSU other than periodic testing and replacement of the standby battery Refere...

Page 8: ...proved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution Ri...

Reviews: