Protective Earth 
 

 

Short circuit proof transformer 
 
 

 DC polarity 

 
 

for Internal use only 

 Mains Present indication 

 
 
 

  Fault indication (see product manual) 

 
 

Risk of Electric Shock 

 Mains  

             should be isolated before attempted access 
 
 

  Device is Double insulated  

 

 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 
This product falls within the scope of EU Directives  2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EU  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 
Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries 
safely for onward transport to your supplier, collection point or disposal facility. 
 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 
See  Specification  for  battery  type  information.  The  battery  is  marked  with  the  crossed  out  wheelie  bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 
 

For more information see: 

www.recyclethis.info

 

 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly.

 

Summary of Contents for STX2401-MOD

Page 1: ...arge protection prevents premature battery failure when operating from standby for extended periods Two sets of volt free solid state relay fault output signal i loss of mains and ii battery fault cha...

Page 2: ...charging Imax A 1 5A 1 2A 1 5A 1 2A Battery Capacity eg PowerSonic model Yuasa model 2 x 1 2Ah 12V PS12021 NP1 2 12 2 x 7Ah 12V PS12070 NP7 12 Battery Charging Constant current bulk charging to 80 cap...

Page 3: ...S Fault GEN Fault Condition Possible Cause Action CLOSED CLOSED Normal operation Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mains C...

Page 4: ...ctive Battery charging normally but 90 of full charge None 2 PULSES ON No Battery Battery disconnected Battery fuse blown Battery heavily discharged Check battery connections Check battery fuse Check...

Page 5: ...ard with a 5A or greater current capacity i e 0 75mm2 nominal conductor area having a minimum operating voltage of 300 500V ac 2 The low voltage output cable must be sized to carry the rated load curr...

Page 6: ...Negative terminals of the batteries to the PCB terminals Batt and Batt using the cables provided See Figure 2 and 3 13 Connect the battery temperature sensor two white wires to the PCB terminals Temp...

Page 7: ...ENANCE This unit is intended for use by Service Personnel only There are NO USER SERVICEABLE parts inside There is no regular maintenance required of the PSU other than periodic testing and replacemen...

Page 8: ...ed via an appropriate approved WEEE disposal route in accordance with all national and local regulations Before disposal of the product any batteries must be removed and disposed separately via an app...