Technical Support Line + 44 (0) 2392 739412
Issue 3 April 2002 - INT200E
PAK200336
ELMDENE INTERNATIONAL LIMITED
RODNEY ROAD
FRATTON
PORTSMOUTH
PO4 8SS, UK
TEL: +44 (0) 2392 739412
FAX: +44 (0) 2392 811631
INT200E Internal Sounder
High Output Internal Sounder
Internal Sounder ideal for domestic or commercial applications requiring a high siren output.
•
115dB(A) nominal siren output with adjustable trim control.
•
9-15Vdc working voltage range with polarity reversal protection.
•
SAB function using internal PP3 Battery (not supplied).
•
Battery type selectable (dry cell or rechargeable).
•
Ring when powered option (if required).
•
Selectable Positive or Negative ring input (control signal).
•
Hold-off supply failure detection.
•
Front and rear tamper.
•
Tamper signalling via voltfree contacts (contacts open in tamper active condition).
•
Designed to comply with BS EN50131-1: 1997. Security Grade: 2. Environmental Class: II.
Specification
Siren Output
115dB (A) nominal acoustic level @ 1m.
Power supply
12Vdc nominal (range: 9 - 15Vdc). Protected against polarity reversal.
Current Consumption
400mA for full alarm, 1mA standby.
Operating frequency
2.6KHz nominal (adjustable using TRIM pot over range 1.3 - 3.5KHz).
SAB Facility
9V PP3 battery, dry cell or rechargeable.
Tamper
0.5A @ 30Vdc N/O voltfree contacts
Operating temperature
-10 to +40°C (operating), -20 to +80°C (storage)
Humidity
95% RH non-condensing maximum.
Case Dimensions
160mm x 110mm x 40mm
Connections
H+
+12Vdc nominal positive hold-off supply (bell supply).
H-
0V negative hold-off supply (bell supply).
TMP 1 & 2
Tamper switch N/O contacts (contacts open in tamper active
condition).
RING
Alarm input. Selectable 0V (R-) or 12Vdc nominal (R+) to activate
sounder (unless ring when powered option selected).
BATTERY
Flying lead to PP3 type battery.
Mode Selection
JP1
Battery Type Selector: Link = PP3
RECHARGEABLE
battery
ONLY
.
No link = PP3
DRY
cell battery.
JP2
R-/R+ selection:
Link pins 1+2 (R-) , 0V to activate sounder.
Link pins 2+3 (R+), 12Vdc to activate
sounder.
Factory Default = PP3 dry cell and R- ring input
Driving Sounder from Power Supply Connection (ONLY) – Ring when
powered option
1)
Make permanent connection from H- terminal to R- terminal.
Ensure JP2 pins 1+2 linked.
2)
Unit will sound continuously when powered via H+ / H- connections.
Installation and Set-up
1)
Remove sounder cover.
2)
Remove knock-outs from sounder baseplate as required.
3)
Adjust tamper switch blade as required.
4)
Select required PP3 battery type using JP1 jumper link (dry cell or rechargeable).
5)
Select required RING (control) signal polarity using JP2 jumper link.
6)
Pass wires from control panel through knock-out hole(s).
7)
Fix backplate to wall with screws through mounting slots.
8)
Set ‘TRIM’ control pot. to mid position.
9)
Connect RING terminal of sounder to ring (bell) output of control panel (unless sounder driven
from single power supply connection – see above).
10)
If Tamper circuit used, connect TAMP1/2 terminals to appropriate inputs on control panel.
11)
Connect n12Vdc and 0V supply from control panel to H+ and H- terminals
respectively.
12)
Replace sounder cover.
Testing
Sounder driven from Power Supply Connection – Ring when powered option
1)
Connect sounder to n12Vdc and 0V supply (from control panel) if single connection
used.
2)
Check output from sounder. Remove cover and adjust ‘TRIM’ control pot. as required. Replace
cover.
Conventional Panel Connections
1)
Activate ring (bell) output from control panel and check output from sounder. Remove cover
and adjust ‘TRIM’ control pot. as required.
2)
Check that the panel detects a tamper failure, if tamper connections used.
3)
Replace cover. Check that the tamper active output condition has cleared at the control panel.
4)
Fasten cover screw.
CAUTION
This unit is NOT SUITABLE for
external installation.
Risk of explosion if dry cell
battery used with JP1 link
fitted.
Dispose of used batteries
according to the battery
manufacturer’s
instructions and all local and
national regulations.
TAMPER
SWITCH
JP2 LINK
(RING POLARITY)
JP1 LINK (FIT FOR
RECHARGEABLE
PP3 BATTERY)
TRIM POT
CONTROL
PP3 BATTERY
Note: Ensure
battery locates
hard against
(central) end stop.