EN3-34-U 13.8Vdc 3.0A with 2 x 17Ah Batteries 

EN50131-6 Grade 3 PSU 

 

F

EATURES

 

 

 

Suitable for use in systems designed to comply with PD6662:2010 to Grade 3 and Environmental Class II. Rated to provide 

continuous current to load

 for systems requiring 34Ah standby from two batteries. Each battery has its own independent 

charger and monitoring circuits. Three independent output signals are provided for loss of mains fault (EPS), battery fault 
(APS), and power supply fault (PSU). Comprehensive self-diagnostics can detect blown output and battery fuses, battery fail, 
low battery voltage and low output voltage. The PSU incorporates intelligent battery management comprising active full 
load battery testing, low battery voltage detection and deep discharge protection to ensure that the batteries are not 
permanently damaged through excessive discharge. A brownout filter ensures that short mains voltage dips do not create a 
false loss of mains alarm. Diagnostic LEDs assist with quick and easy installation by showing presence of mains, correct 

individual

 battery charging or a fault condition. Comprehensive protection is built-in as standard including mains transient 

filtering, transformer thermal fuse, electronic output overload protection and fuses on the load and battery outputs. 

 

EN50131-6:2008 Grade 3 Type A PSU

*

 

 

EN50131-1 Environmental Class II

*

 

 

Independent Intelligent Active Battery Monitoring on each battery 

 

Low quiescent battery monitoring current during standby operation 

 

Fault signals for loss of mains, battery fail and power supply fault 

 

Battery Deep Discharge Protection. 

 

Protection against reverse battery connection. 

 

Electronic overload protection shuts down output until overload or short circuit is removed (while on mains power). 

 

Transformer thermal fuse 

 

Mains transient suppression and brown-out filter 

*

When installed in an enclosure that provides the required tamper arrangement and EMC shielding. 

C

OMPLIANCE

 

 

This power supply unit complies with the following European Directives: 
Low Voltage 2014/35/EU 

 EMC 2014/30/EU  

 WEEE 2012/19/EU          

*

When installed in an enclosure that provides the required tamper arrangement and EMC shielding.

 

S

PECIFICATION

 

 

 

Input 

Voltage 

 

 

230Vac (+10% / -15%), 50Hz nominal 

Current 

 

 

640mA  (Nominal at full load) 

Mains input fuse 

 

T2.0A 20mm, 250Vac HRC 

 

Output 

Voltage 

 

 

13.4 - 14.0 Vdc (Mains power 10% / -15%) 

 

 

 

9.6 – 13.0 Vdc (13.8 Vdc nominal) (Battery Standby) 

Load Current (Continuous) 

3A (Mains power) 

 

 

 

2.8A

*

 (with 2 x 17Ah batteries) (

12 hours

 

 

 

1.4A

*

 (with 2 x 17Ah batteries) (

24 hours

 

 

              

 