background image

 
 

 

                   Elma Laser X2 

 

Use of instrument 

Application areas 

 

            Horizontal                            Vertical                             Cross 

General 

When the lock mechanism is opened, the instrument turns on and auto 
leveling is activated. When the instrument is on, switch between 
horizontal, vertical and cross laser by short pressing the “On” button on 
top of the instrument. Always lock the instrument before switching off, 
by clicking the “Off” button on top of the instrument. 

Auto leveling 

Auto leveling is activated when the lock button is in the “open lock” 
position. If the laser is out of level by more than 4˚ (on a sloping surface), 
the laser blinks at a fast pace as warning, that auto leveling is not active. 

Pulse 

In auto leveling mode, pulse mode can be activated, for detection using  
standard laser detectors, for long-range detection. Push the “On” button 
for >3 seconds. The laser blinks 5 times, indicating pulse mode. Pulsating 
laser can be detected using standard detectors for green lasers. Notice 
that the visual laser will appear weaker in pulse mode. 

Manual leveling 

Manual leveling is active when the lock button is in “locked” position. 
When locked, the instrument can be positioned in every angle, to mark 
the desired angle. Notice that horizontal/vertical leveling is deactivated. 
The laser will blink about every 3 seconds, to indicate manual leveling. 

Summary of Contents for 5706445677009

Page 1: ...Elma Laser X2 Dansk Norsk 2 Svenska 5 English 8 EAN 5706445677009...

Page 2: ...sikkerhedsinstruktioner i manualen Bem rk faresymboler p instrumentet som advarer om laserklasse og sikkerhed Kig ikke direkte in i laserstr len Adskil og modificer ikke instrumentet p nogen m de da d...

Page 3: ...r de p 4 placeret p sk vt underlag blinker laseren hurtigt Puls I selvnivelleringstilstand kan puls for standard detektor anvendes for at ge afstand til detektering af laserlinje Tryk p t nd knappen i...

Page 4: ...kal instrumentet opbevares i l ngere tid b r batterier fjernes fra batterirummet for at undg batteril k i instrument Instrumentet kan reng res med en let fugtig klud Anvend aldrig opl sningsmidler Spe...

Page 5: ...etsinstruktionerna i manualen Notera varningssymboler p instrumentet som varnar om laserklass och s kerhet Titta inte direkt in i laserstr len Tag inte is r och modifiera inte instrumentet p n got s t...

Page 6: ...eringsomr det p 4 placerad p oj mnt underlag blinkar lasern snabbt Puls I sj lvnivelleringsl ge kan puls f r standarddetektor anv ndas f r att ka avst ndet f r detektering av laserlinjen Tryck p ON kn...

Page 7: ...Om instrumentet skall f rvaras under en l ngre tid b r batterierna tas ur batteriutrymmet f r att undvika batteril ckage i instrumentet Instrumentet kan reng ras med en l tt fuktad trasa Anv nd aldrig...

Page 8: ...afety instruction in the manual Notice warning symbols on the instrument showing laser class and safety Never stare directly at the laser beam Never disassemble or modify the instrument in any way as...

Page 9: ...n 4 on a sloping surface the laser blinks at a fast pace as warning that auto leveling is not active Pulse In auto leveling mode pulse mode can be activated for detection using standard laser detector...

Page 10: ...f the instrument is stored for an extended period remove the batteries to avoid battery leak inside the instrument The instrument can be cleaned using a slightly damp cloth Never use solvents Specific...

Page 11: ...Elma Laser X2 11...

Page 12: ...Elma Laser X2 12...

Reviews: