Elma 5706445677009 Manual Download Page 10

 
 

 

                   Elma Laser X2 

10 

 

Maintenance 

The instrument is factory calibrated, to comply the specified accuracies. 
It is recommended to check accuracy before use, comparing to known 
vertical and horizontal lines. 

When the instrument is not in use, is should be turned off and locked, to 
protect the pendulum suspension for auto leveling. 

If the instrument is stored for an extended period, remove the batteries, 
to avoid battery leak, inside the instrument. 

The instrument can be cleaned using a slightly damp cloth. Never use 
solvents. 

Specifications 

Technical data  
Visual range: 

 

To 45 meters (depending of ambient light) 

Horizontal accuracy: 

 

±2mm@10m 

Vertical accuracy: 

 

±2mm@10m 

Auto leveling:  

 

≤4˚ 

Auto level time: 

 

≤3s

 

Laser: 

 

Class II 510nm, 40 mW 

Mount thread: 

 

¼ inch 

Battery: 

 

4 pcs. AA 1,5V (incl.) 

Battery life: 

 

≥4t @ 2 lines 

Protection category: 

 

IP54 

Dimensions: 

 

135x125x80mm 

Weight: 

 

240g 

 
 
 
 
 
 

Summary of Contents for 5706445677009

Page 1: ...Elma Laser X2 Dansk Norsk 2 Svenska 5 English 8 EAN 5706445677009...

Page 2: ...sikkerhedsinstruktioner i manualen Bem rk faresymboler p instrumentet som advarer om laserklasse og sikkerhed Kig ikke direkte in i laserstr len Adskil og modificer ikke instrumentet p nogen m de da d...

Page 3: ...r de p 4 placeret p sk vt underlag blinker laseren hurtigt Puls I selvnivelleringstilstand kan puls for standard detektor anvendes for at ge afstand til detektering af laserlinje Tryk p t nd knappen i...

Page 4: ...kal instrumentet opbevares i l ngere tid b r batterier fjernes fra batterirummet for at undg batteril k i instrument Instrumentet kan reng res med en let fugtig klud Anvend aldrig opl sningsmidler Spe...

Page 5: ...etsinstruktionerna i manualen Notera varningssymboler p instrumentet som varnar om laserklass och s kerhet Titta inte direkt in i laserstr len Tag inte is r och modifiera inte instrumentet p n got s t...

Page 6: ...eringsomr det p 4 placerad p oj mnt underlag blinkar lasern snabbt Puls I sj lvnivelleringsl ge kan puls f r standarddetektor anv ndas f r att ka avst ndet f r detektering av laserlinjen Tryck p ON kn...

Page 7: ...Om instrumentet skall f rvaras under en l ngre tid b r batterierna tas ur batteriutrymmet f r att undvika batteril ckage i instrumentet Instrumentet kan reng ras med en l tt fuktad trasa Anv nd aldrig...

Page 8: ...afety instruction in the manual Notice warning symbols on the instrument showing laser class and safety Never stare directly at the laser beam Never disassemble or modify the instrument in any way as...

Page 9: ...n 4 on a sloping surface the laser blinks at a fast pace as warning that auto leveling is not active Pulse In auto leveling mode pulse mode can be activated for detection using standard laser detector...

Page 10: ...f the instrument is stored for an extended period remove the batteries to avoid battery leak inside the instrument The instrument can be cleaned using a slightly damp cloth Never use solvents Specific...

Page 11: ...Elma Laser X2 11...

Page 12: ...Elma Laser X2 12...

Reviews: