Senko Multi Gas Detector
25
3.5.1 Display Mode in Details
LCD Display Images
Description in Detail
➢
Measuring Mode (Basic Display)
➢
Display the current gas levels of the atmosphere and the
battery power level
➢
A minimum gas concentration detected by the device.
*In an ambient air, the Oxygen level normally indicates
20.9%vol.
➢
A maximum concentration detected by the device.
*In an ambient air, the Oxygen level normally indicates
20.9%vol.
➢
Acceptable hourly average exposure levels of the toxic gases
for the last eight hours (Time Weight Average)
➢
Acceptable average exposure levels of the toxic gases for the
last 15 minutes (Short Term Exposure Limit)
➢
Clear the previous Low, High (Peak), TWA, STEL values.
➢
Check the current setting values manually.
(Low alarm, High alarm, TWA, STEL)
➢
Check the firmware version and type (N type or P type)
➢
Check on set SPAN calibration levels
➢
Mode for ZERO calibration and SPAN calibration
➢
Current Date and Time
Summary of Contents for Senko MGT