Elma Laser X360
10
Puls
Push button “P” to activate laser pulse for standard detectors. Laser lines
can be detected by standard detectors for green lasers, when in pulse
mode. Notice that the visual laser will appear weaker in pulse mode.
Maintenance
The instrument is factory calibrated, to comply the specified accuracies.
It is recommended to check accuracy before use, comparing to known
vertical and horizontal lines.
When the instrument is not in use, is should be turned off and locked, to
protect the pendulum suspension for auto leveling.
If the instrument is stored for an extended period, remove the batteries,
to avoid battery leak, inside the instrument.
Clean the instrument using a slightly damp cloth. Never use solvents.
Specifications
Technical data
Visual range:
To 45 meters (depending of ambient light)
Horizontal accuracy:
±3mm@10m
Vertical accuracy:
±3mm@10m
Auto leveling:
≤4˚
Auto level time:
≤5s
Laser:
Klasse II 510nm, 40 mW
Mount thread:
¼ and 5/8 inch
Battery:
Rechargeable Li-Ion, 4,2V, 5200mAh (incl.)
Power supply:
230V to Micro USB (Incl.)
Batterilevetid:
≥5t @ 3 linjer
Kapslingsklasse:
IP54
Dimensioner:
187x245x187mm
Vægt:
480g