8. Canopy Assembly.
page 6
7. Wiring.
canopy
hanging bracket
slotted
hole
black
black
white
white
black supply wire
ground
(green
or bare)
white supply wire
*
from ceiling
from fan
ground
(green or bare)
blue
Raise canopy to hanging bracket, aligning
slotted holes in canopy with loosened screws
in hanging bracket. Twist canopy to lock.
Insert screws (with star washers) that were
previously removed (page 3, Section 4) and
secure all screws with Phillips screwdriver.
CAUTION:
Be sure outlet box is properly
grounded and that a ground (
GREEN
or Bare)
wire is present.
Make sure all electrical connections comply
with Local Codes or Ordinances and the
National Electrical Code. If you are unfamiliar
with electrical wiring or if the house/building
wires are different colors than those referred to
in the instructions below, please use a qualified
electrician.
When downrod is secured in place on the
hanging bracket, electrical wiring can be
made
as follows:
Connect
BLACK
wire from fan to
BLACK
wire
from ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires
together from fan to
BARE
/
GREEN
wire from
ceiling with wire connector provided.
Since this fan does not come with a light kit,
you will need to cap off the
BLUE
wire with a
wire connector (as shown with arrow in
diagram). [
Note
: If you elect to purchase a
light kit for the fan, the
BLUE
wire from the
fan must be connected to the
BLACK
wire
from the ceiling instead.]
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote adaptable (remote control