2.3 Mounting
Determination of installation location: The inverter/charger shall be installed in a place with sufficient air flow through the
dissipation pad of the controller and a minimum clearance of 150 mm from the upper and lower edges of the controller to
ensure natural thermal convection. Please see Figure 2 -1 Mounting
5
NOTE: The wire size used for connection is for reference only, use thicker wires to lower the voltage drop
and improve the system performance when the distance between the whole solar system components is far.
NOTE: The above wire and the circuit breaker size are for recommended use only, please choose the
suitable wire and circuit breaker according to the practical situation.
WARNING: Risk of explosion!
Never install the controller with
flooded batteries in a sealed
enclosure! Do not install the
device in a confined area where
battery gas can accumulate.
6
Installation Steps
Step 1: Determination of Installation Location and Heat-dissipation Space
Step 2: Take down the terminal protective cover
Figure 2 - 1 Mounting
Screw off the screws and take
down the terminal protective cover
of the inverter/charger before
wiring.
NOTE
:
The cable lugs refer to the cardboard in the package.