5.1 Fault

14

4. Protection

5. Troubleshooting

 

Protection

Instruction

PV Limit Current

PV Short Current

PV Reverse Polarity

Night Reverse Charging  

When the charging current of the PV array exceeds its rated current, it will be charged at 
the rated current. NOTE: When the PV modules are in series, ensure that the open circuit 
voltage of the PV array does not exceed the "maximum PV open circuit voltage". 
Otherwise the inverter/charger may be damaged. 

When PV is not charging and short circuit, the inverter/charger is not damaged. 

Fully protection against PV reverse polarity, correct the wire connection to resume normal 
operation. NOTE: The inverter/charger will be damaged when the PV array straight polarity 
and the actual operation power of the PV array is 1.5 times greater than the rated charge 
power! 

Prevent the battery discharging through the PV module in the night. 

Utility Input Overvoltage 

When the utility voltage exceeds 280VDC, it will stop utility charging/discharging. 

Utility Input Under Voltage 

When the utility voltage less than 160VDC, it will stop utility charging/discharging. 

Battery Overvoltage 

When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage,
the inverter/charger will stop charging the battery to protect the battery from being over 
charged to break down. 

Battery Over Discharge 

When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage, the 
controller will stop discharging the battery to protect the battery from being over
discharged to break down. 

Load Output Short Circuit 

Load Output Overload 

Device Overheating 

It will immediately close the output in occurrence of short-circuit and hereafter the output
is automatically recovered in time delay (the first time delay for 5s, the second time delay 
for 10s, the third time delay for 15s); if the short-circuit remains after 3 times of delay, 
restart the inverter/charger only after clearing the fault. 
Overload

105%  

 

130% 

  

160% 

                

180%

15min.  

30s  

 

10s  

                   5s 

The first time delay for 5s, the second time delay for 10s, the third time 
delay for 15s 

Recover 3 
times

The inverter/charger will stop charging/discharging when the internal temperature is too 
high, and will restore charging/discharging when the temperature is recovered to normal. 

Continuance 

Module 

Code  

Fault 

Battery 

frame 

blink 

Indicator 

Buzzer 

Fault 

indicator 

Battery 

BLV   

Battery Low Voltage

 

Flashing 

— 

— 

— 

BOV    Battery Over Voltage

 

Alarm 

On 

Solid 

BOD  

Battery Over discharge 

NVE  

Nominal Voltage  Error

 

LTP 

Low Temperature

 

PV 

charging 

module 

OTP  

Over Temperature

 

(PV Charge Module)

 

— 

PV charge   

Fast 

Flashing 

CFA  

Communication Fault 

Alarm 

Utility 

charging 

module 

IOV   

Input Over Voltage 

Utility        

Fast 

Flashing 

ILV   

Input Low Voltage

 

OTP  

Over Temperature

 

(Utility Charge Module)

 

CFA  

Communication Fault 

Alarm 

Inverter 

output 

module 

OVA  

Output Over Voltage 

Inverter       

Fast 

Flashing 

IOS   

Input Low Voltage

 

OOL  

Output Over Load 

OTP  

Inverter  Temperture 

CFA  

Communication Fault 

Alarm 

Summary of Contents for FBIC3000VA/24V

Page 1: ...3000VA Inverter Charger FBIC3000VA 24V FBIC3000VA 48V User Manual Please read this guide carefully before using this product...

Page 2: ...devices The UPower series is a new type of the inverter charger combining with solar utility charging and AC output which adopts a multi core processor design and advanced MPPT control algorithm and...

Page 3: ...vanced interface Multiple LED indicators that instantly indicate the operating state of the system 2P circuit breaker provided at the utility input end Independent control of AC output by AC OUT butto...

Page 4: ...Schematic Diagram for Connections Warning Confirm the AC load power compatible with the power of the inverter charger AC load selected exceeding the maximum output power of inverter charger is prohib...

Page 5: ...t density in accordance with Article 690 of the National Electrical Code NFPA 70 For outdoor installation keep out of the direct sunshine and rain infiltration High voltage still exists inside the inv...

Page 6: ...above wire and the circuit breaker size are for recommended use only please choose the suitable wire and circuit breaker according to the practical situation WARNING Risk of explosion Never install th...

Page 7: ...he thicker wire wire is not less than 4mm2 the grounding point shall be as close as possible to the inverter charger the grounding wire shall be as short as possible AC output Ground and PV wiring ter...

Page 8: ...d Utility Turn on the AC load when the AC output is normal NOTE The temperature sensor short circuited or damaged the inverter charger will be charging or discharging at the default temperature 250C N...

Page 9: ...t On Solid Load output Green OFF Relay turn off On Solid Relay turn on Green OFF Inputvoltage 3 3 12VDC On Solid No Inputvoltage Green OFF Inverter output On Solid Utility output Red OFF Device normal...

Page 10: ...ace 9 Icon instruction Icon instruction Utility connected PV connected No Utility No PV Load ON Load OFF Battery capacity level 8 25 Battery capacity level25 50 Battery capacity level 50 75 Battery ca...

Page 11: ...Battery Type AGW GEL FLD USER INPUT Solar priority The battery is charged in solar priority modeand when the battery voltage is lower than Auxiliary Module ON Voltage VAON the utility starts charging...

Page 12: ...on again for confirmaton Step 4 Press the button to exit the setting interface Setting Item LCD Instruction Default Range 1 BTP Battery type AGM AGM GEL FLD USER 2 CSP Charge source priority Solar pri...

Page 13: ...module ON voltage 28 0VDC User 24 0 29 6VDC Step size 0 2VDC 16 AON 24 0 VDC 17 DON 22 2 VDC User 21 6 24 0VDC Step size 0 2VDC 18 DOF Dry connect OFF voltage Dry connect ON voltage 24 0 VDC User 24 0...

Page 14: ...is energized and the switch is turned on The dry contact can drive resistive loads 125VAC 1A 30VDC 1A NOTE When the utility input is abnormal this dry contact can control the generator switch to char...

Page 15: ...the set point of Low Voltage Disconnect Voltage the controller will stop discharging the battery to protect the battery from being over discharged to break down Load Output Short Circuit Load Output O...

Page 16: ...vironment Make sure no block on air flow around the inverter charger Clear up any dirt and fragments on radiator Check all the naked wires to make sure insulation is not damaged for serious solarizati...

Page 17: ...me 20mS Max PV Open Circuit Voltage 150V 138V Max PV Input Power 780W 1040W PV Charging Current 30A 20A Equalization Voltage 29 2V 58 4V Boost Voltage 28 8V 57 6V Utility Input Solar Charging Others M...

Page 18: ...17 NOTES...

Page 19: ...18 NOTES...

Page 20: ...Help Line South Africa 0861 ELLIES 355437 For branch or agent contact details please refer to website www ellies co za...

Reviews: