MEDEA Installation Manual
89
7.5
ER700-RF expansion module
Nominal power voltage
13.8 V
⎓
Working voltage
… V
⎓
Consumption
58 mA
Manageable RF devices
Detectors
: 28 max.
Sirens
: 4 max.
Keypads
: 4 max.
Remote controls
: 8 max.
Dimensions (W x H), mm
89 x75
Maximum bus length
(cable cross-section 2x0.75 mm
2
power 2x0.22
mm
2
data)
500 metres
7.6
ILT700 interface
Nominal power voltage
13.8 V
⎓
Working voltage
10 - 14.5 V
⎓
Rated current consumption at 13.8 V
⎓
Stand-by
: 15 mA
During active communication
: 17 mA max.
Dimensions (L x H)
40 x 70 mm
Classification according to EN50136-2
1
SP2-DP1
1. The line control must be enabled with a time not exceeding 25h to ensure compliance with EN50136-2
in the configuration of the interface.
DP1 guaranteed with
:
Primary ILT-700 interface and LAN connector or alternative IT700-GSM interface, with periodic test not
exceeding 25h enabled.
7.7
IT700-GSM interface
Nominal power voltage
13.8 V
⎓
Working voltage
10 - 14.5 V
⎓
Rated current consumption at 13.8 V
⎓
Stand-by
: 10 mA
Transmission
: 200 mA max.
Frequencies used
850/900/1800/1900 MHz
GPRS data transmission
Receiving up to 85.6 Kbps
Transmitting up to 42.8 Kbps
SIM card format
Nano-SIM
Dimensions (L x H)
40 x 70 mm
Classification according to EN50136-2
1
SP2-SP4, DP1-DP2
The line control must be enabled with a time not exceeding 25h to ensure compliance with EN50136-2 in
the configuration of the interface. (SP2) or 3 min. (SP4).
DP1 guaranteed with
:
IT700-GSM primary interface and ILT700 alternate interface.
DP2 guaranteed with
:
IT700-GSM primary interface and alternative LAN connection with 30 min periodic test.