DS80KP55-001C
Blue LED on: the system is off.
Blue LED blinking: error for the following reasons:
No reply sent to control unit within 4 seconds.
Incorrect error code. If an incorrect disarming code is entered five times, the system will be blocked and
the keypad will be deactivated
for approximately 9 minutes, during which normal operation cannot be
restored even if the correct disarming code is entered or by operating from the app and portal ("Key
locked" will appear in the “Event Log” on the local control panel). Repeating an incorrect code will extend
the time by 9 more minutes.
Request to pass to Partial Armed state when the Total Armed state.
Forced arming request.
F
F
a
a
u
u
l
l
t
t
L
L
E
E
D
D
(
(
a
a
m
m
b
b
e
e
r
r
)
)
:
:
Blinking: system error (control unit tamper, power fault, detector tamper, detector fault, door open, etc.)
On: alarms have occurred.
P
P
o
o
w
w
e
e
r
r
The remote keypad is powered by an EL 123AP lithium battery.
The remote keypad can detect the battery state. If battery voltage is low, the keypad state LED will blink (amber in Test
mode or blue in normal mode) during normal operation. The discharge battery signal is sent to the control unit during
normal transmission to view the respective state.
The battery is pre-installed in the factory.
E
E
n
n
e
e
r
r
g
g
y
y
s
s
a
a
v
v
i
i
n
n
g
g
m
m
o
o
d
d
e
e
The remote keypad is in stand-by mode and does not use current when it is not in use. It is activated for 5 seconds when
any button is pressed.
It switches off and goes back to stand-by mode if no button is pressed for 5 seconds.
After having entered a control, the remote keypad is switched off and goes back to stand-by mode.
T
T
e
e
s
s
t
t
m
m
o
o
d
d
e
e
The remote keypad may be set to Test mode by entering the keypad code (default: 0000) followed by button
*
. The
amber state LED lights up and a long beep will sound.
To exit Test mode, press the button twice
, the remote keypad will generate a long beep, the keypad state LED will
be switched off and the remote keypad will return to normal operating mode. Otherwise, the remote keypad will
automatically shut down Test mode after 5 minutes and go back to normal operating mode.
<
<
N
N
O
O
T
T
E
E
>
>
Test mode is useful to exclude the tamper alarm of the remote keypad during installation, during battery replacement
or if it is moved to another installation site.
When the remote keypad is in Test mode it is always active and will NOT switch off automatically after 5 seconds.
Test mode operation:
Press button
*
and then button 7 — The control unit transmits remote keypad learning data
Press button
*
and then button 2 — Panic alarm function on
Press button
*
and then button 5 — Panic alarm functions off (default)
Press button
*
and then button 6 — Change keypad code
Enter the old remote keypad code and press the button
Enter the new 4-digit keypad code and press the button #.
Press button
twice — Exit Test mode.
Press button
*
and then button 8 — Arming mode without user code on.
Press button
*
and then button 9 — Arming mode with user code on (default).
T
T
a
a
m
m
p
p
e
e
r
r
p
p
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
The keypad is protected from any attempt to open the cover or remove it from the installation surface.
The Tamper protection is not on when the keypad is in Test mode.
L
L
e
e
a
a
r
r
n
n
i
i
n
n
g
g
p
p
r
r
o
o
c
c
e
e
d
d
u
u
r
r
e
e
Step 1:
Set the control unit to
learn mode
.
Step 2:
Add the remote keypad in the control unit:
Test mode learning
I. Set the remote keypad in Test mode by entering the keypad code (pre-set:
0000
) followed by
button
*
. The amber state
LED lights up and a long beep will sound.
II. Press button
*
and then button 7. The remote keypad will generate a long beep.
<
<
N
N
O
O
T
T
E
E
>
>
If the remote keypad does not generate a long beep, it means that no learning data has been sent to the
control unit; press button * and then button 7 to send the learning data again.
III. The respective information will be shown if the control unit receives the learning data. Refer to the control unit
instruction manual to complete the learning procedure.
IV. After having received the remote keypad signal, the control unit will send a confirmation to the remote keypad. The
remote keypad will beep three times to confirm that validation was received.