DOUBLE KNOCK FUNCTION
The EIR has a double knock function. If the double knock function is enabled, the EIR will report an
alarm to the Control Unit only if two movements are detected within 10 seconds. If the double knock
function is disabled, the EIR will report an alarm to the Control Unit whenever a movement is detected.
DIP SWITCH POSITION TABLE
The function of each DIP Switch is listed as the table below. The DIP Switch is either
ON
or
OFF
. Top
position indicates
ON
and bottom position indicates
OFF
.
DIP
Position
Function
DIP
Sensitivity Level
ON Test
Mode
Switch 5
Switch 6
Switch 1
OFF
Normal Mode (default)
ON
ON
Low; for 75 cm / 60 kg pet
ON
Supervision Disable
ON
OFF
Medium; for 60 cm / 40 kg pet
Switch 2
OFF
Supervision Enable (default)
OFF
ON
High; for 45 cm / 30 kg pet
ON
EIR facing a wall within 10 m
OFF
OFF
Superior; for 30 cm / 20 kg pet (default)
Switch 3
OFF
EIR facing an open space
(no wall within 10 m) (default)
DIP
Position
Function
ON
EIR facing a lawn (default)
ON
Double Knock Enable (default)
Switch 4
OFF
EIR facing a concrete/stone ground
Switch 7
OFF Double
Knock
Disable
ON
Switch 8
OFF
Reserved
GETTING STARTED – LEARNING THE EIR IN THE CONTROL UNIT MANUAL
•
Loosen the fixing screws and remove the cover assembly.
•
Based on your needs, set Sensitivity Switch as shown in
DIP Switch Position Table
.
•
Insert two 3.6V AA lithium batteries into the battery holder taking care to connect the polarity
correctly.
•
The LED indicator will flash for 30 seconds. The EIR is warming up. During the warming period,
the EIR is not activated. It is recommended that you stay away from the detection area during this
time. After the warming period is over, the LED dims and the EIR is ready to operate.
•
Navigate the Control Unit into “
/-
” menu and then select “
Add Device
” menu.
•
Press the Test button on the front cover.
•
Refer to the operation manual of your Control Unit under the section “
/-
” to complete the
learn-in process (for certain Control Unit models, the EIR can be learnt in as a regular PIR with
programmable attributes and thus the Control Unit will report when an alarm is triggered).
•
After the EIR is learnt-in, navigate the Control Unit into “
Walk Test
”. Hold the EIR in the desired
location, and press the Test button to confirm this location is within the signal range of the Control
Unit.
•
When you are satisfied that the EIR work in the chosen location, you can proceed to installation.
Note:
Walk Test
should be conducted to confirm proper operation and coverage of the EIR.
ON
OFF