C420 Programming Manual
3.2.3.1
Name
By selecting this item, the user can enter the name of the zone (if a name has been already assigned to the zone previously, it is
displayed and the cursor blinks beyond the last character).
After having entered the characters which compose the name, ACK confirms the string entered and the previous menu is shown.
By pressing ESC, the previous menu is shown and the inserted modifications are discarded.
3.2.3.2
Mode
By selecting this item, the following menu of choice of working mode of the zone is shown:
Each mode involves the insertion of a set of parameters, according to the table below (
*
indicates that the parameter must be
specified for the selected mode):
MODE
DELAY
MASTER
ALARM
ALARM
CONFIRMATION
SINGLE KNOCK
*
SINGLE KNOCK WITH DELAY
*
*
DOUBLE KNOCK
*
DOUBLE KNOCK WITH DELAY
*
*
HOTEL
*
*
After having selected the working mode, a sequence of screens is shown for the settings of the parameters associated to the
chosen mode.
DELAY
This is the delay whose expiration makes the zone in alarm with siren output OFF switch to alarm condition with siren output ON.
The valid range for this parameter is 1
– 10 minutes.
The delay is inserted through the following screen:
After inserting and confirming the delay by pressing ACK, the screen related to the next parameter for the selected mode is shown.
MASTER ALARM
When this option is enabled, if the zone goes to alarm condition with siren output ON the master alarm is activated (this leads to
the activation of all the zone relays, all the siren outputs, the alarm relay and the siren relay):
Use the UP/DOWN keys to select the activation/deactivation of this option, then confirm the choice by pressing the RIGHT key.
ZONE: XX
NAME: _
> SINGLE KNOCK
SINGLE KNOCK WITH DELAY
DOUBLE KNOCK
DOUBLE KNOCK WITH DELAY
HOTEL
DELAY: XX
MASTER ALARM
> YES
NO