background image

4 / 4

 AirCFS-100S

Warning

Technical parameters

Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is 
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualifi cation upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free 
function of the device also depends on transportation, storing and handling. In case you 
notice any sign of damage, deformation, malfunction or missing part, do not install this 
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated.  Before starting installation, make sure that all 
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for 
working with electrical devices. Do not touch parts of the device that are energized – life 
threat.  To ensure the transmission of the radio signal, make sure that the devices in the 
building where the installation is installed are correctly located. Unless otherwise stated, 
the devices are not intended for installation in outdoor and damp areas, they must not 
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents 
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters 
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby 
disabling the remote control. 

Power supply

Battery power:

Battery life by frequency *:

1x 10 minutes

1x 60 minutes

1x 12 hours

1x 24 hours

Setting

Setting:

Alarm Detection:

Battery status view:

Control

Control:

Inputs

Digital sensor:

Measuring range

Temperature sensor:

Tolerance:

Humidity sensor:

Tolerance:

Pressure gauge:

Tolerance:

Communication

Protocol:

Transmitter frequency:

Range in open space:

Transmission power (max.):

Other parameters

 

Working temperature:

Storage temperature:

Operating position:

Mounting:

Protection degree:

Dimension:

Weight:

1x 3.6V LS 14500 Li-SOCl

2

 AA

0.4 years

2.1 years

8.5 years

9.9 years

With a message from the server 

programming cable

message to the server

only when the battery is powered by a message on the server

button SET

Tamper

Temperature, humidity, atmospheric pressure

-40 .. +85 °C

± 1.5 °C

0-100 % RH

± 3% RH

300 - 1250 hPa

± 1.7 hPa

Sigfox

RCZ1 868 MHz

Approx. 50 km**

25 mW / 14 dBm

-30…+60°C  (Pay attention to the operating 

temperature of batteries)

-30…+70°C

sensor down

glue / screws

IP65

 189 x 62 x 34 mm

122 g (Without battery)

The company ELKO EP, as the manufacturer, is entitled to make technical modifi cations to the 
product, in the technical specifi cation and product manual, without prior notifi cation.

* Values are calculated under ideal conditions
** Depending on network coverage

Summary of Contents for iNELS Air AirCFS-100S

Page 1: ...ssible to use it in agriculture in outdoor areas down sensor e g vineyards orchards It is also suitable for use in harsh indoor areas which require greater protection of the device for example Greenhouses With the wireless solution and Sigfox communication it can communicate instant ly to your chosen location and be operated immediately Data is sent to the server from which it can be subsequently ...

Page 2: ... If necessary clean the battery and contacts prior to using Avoid battery shorts Do not dispose of batteries in water or fire Do not dismantle batteries do not try to charge them and protect them from extreme heating danger of leakage Upon contact with acid immediately rinse the affected area with a stream of water and seek medical attention Keep batteries out of the reach of children If it is sus...

Page 3: ...humidity Threshold Humidity 2 0 100 Threshold level 2 for humidity Threshold Temperature 1 40 120 C Threshold level 1 for temperature Threshold Temperature 2 40 120 C Threshold level 2 for temperature Threshold Pressure 1 900 1250 kPa Threshold level 1 for pressure Threshold Pressure 2 900 1250 kPa Threshold level 2 for pressure UPLINK Byte 0 1 2 3 Bit 7 6 5 4 3 2 1 0 Version FW Subversion FW Vers...

Page 4: ...etal doors this prevents transmission of the radio frequency signal iNELS Air is not recommended for control ling life saving instruments or for controlling hazardous devices such as pumps heaters without thermostat lifts hoists etc radio frequency transmission may be overshad owed by obstruction interference transmitter battery may be discharged etc thereby disabling the remote control Power supp...

Reviews: