COMMON
Power supply (external) :
Power Consumption:
Gain @ 862 MHz :
Attenuation :
Input impedance :
Output impedance :
Input level :
Output level :
No of TV-Channels :
Noise figure :
Isolation between outputs :
Return Path Gain :
CTB:
CSO:
Stop band attenuation :
AV link input level:
AV input frequency range:
Temperature (operating):
Standards :
12 volt DC ± 5% , (Negative (-) put to GND)
3,5 Watt
35 dB (on all 6 ports) ± 2 dB
0 – 20 dB
75 Ohms , F-connector
100 Ohms , Balanced
60 – 80 dB µV
114 dB µV x 6 (Measured according to DIN 45004-B)
41
< 6.5 dB @ 860 MHz
> 20 dB
6 dB
94 dB µV
88 dB µV
> 55 dB
90 dB µV
88-470 MHz
0 - 40 °C
EN 50083-3 , quality grade 2 , cat. C
EL 1030
Frequency range, forward
Return path
47 – 860 MHz
5 - 30 MHz
EL 1055
Frequency range, forward
Return path
70 – 860 MHz
5 - 55 MHz
EL 1065
Frequency range, forward
Return path
85 – 860 MHz
5 - 65 MHz
Technical specifications
Installation
• The cable (R/TV signals) carried to
the distribution board is connected
to the female F-connector (RF input)
on the module. (F-connector for the
cable is not supplied). The amplifier
module is to be regarded as an end-
outlet.
• Power is connected from the ELKO
Link Home Power supply. The
module is protected against wrong
polarity.
• The output level is adjusted from the
Gain regulation. All output ports are
adjusted simultaneously. Tune to an
output level that ensures a signal
between 60 and 80 dBµV at the out-
lets of both the longest and the shor-
test links in the ELKO Link Home
installation. The gain adjust potentio-
meter is located between the power
indicator LED, and IR link port.
• There are no tilt adjustment since the
amplifier has a factory set equaliser
matching the cable attenuation. This
is performing optimal only on the
condition that the incoming signal
connected to the amplifier module
has a maximum tilt of 10 dB and
always lays in the area between 60
to 80 dBµV in terms of the signal
level.
Notice!
If opening the top cover screws, the
guarantee is no longer valid.
When connecting the radio- and TV-
appliances to the wall outlets, it is
necessary to use dedicated ELKO
Link Home connection cords. In these,
the conversion between the 100 Ohm
balanced cabling and the 75 Ohm
coaxial connections on R/TV applian-
ces is carried out.
The 100 Ohm termination plug
MUST be fitted in the AV link port
when leaving the installation.
ELKO A/S, P. O.Box 234, N-1301 Sandvika, Tel: +47- 67 80 73 00 Fax: +47- 67 80 73 01
AB Elektrokontakt, Box 2093, 128 22 Skarpnäck, Tel. 08-447 33 70, Fax. 08-447 33 80